Literature DB >> 8467330

The relationship between quadriceps angle and anterior knee pain syndrome.

D Caylor1, R Fites, T W Worrell.   

Abstract

Anterior knee pain syndrome (AKPS) represents a significant challenge for patients and for clinicians. The purposes of this study were: 1) to determine the reliability of the Q-angle measurement, 2) to quantify Q-angle changes that occur with knee flexion, and 3) to determine if subjects with AKPS (N = 52) have a significantly different Q-angle than subjects without AKPS (N = 50). With the knee in an extended position, intratester Q-angle intraclass correlation coefficients (ICC) ranged from .84 to .90, and standard error of measurement (SEM) values ranged from 2.01 to 2.23 degrees. Intertester Q-angle ICC was .83, and the SEM was 2.49 degrees. With the knee flexed, the intratester ICC was .83 for both testers, and SEM values ranged from 0.68 to 2.45 degrees. Intertester ICC and SEM were .65 and 3.50 degrees, respectively. No significant difference was found in intratester Q-angle values between the extended and flexed knee positions (p > 0.05). No significant difference in Q-angle was found between asymptomatic subjects (11.1 +/- 5.5 degrees) and symptomatic subjects (12.4 +/- 5.1 degrees) (p = 0.07). Increased Q-angles were not responsible for AKPS in this group of patients. Other factors were hypothesized to be responsible for their symptoms.

Entities:  

Mesh:

Year:  1993        PMID: 8467330     DOI: 10.2519/jospt.1993.17.1.11

Source DB:  PubMed          Journal:  J Orthop Sports Phys Ther        ISSN: 0190-6011            Impact factor:   4.751


  19 in total

1.  Relationship of Q angle and joint hypermobility and Q angle values in different positions.

Authors:  Omer Faruk Sendur; Gulcan Gurer; Tuncay Yildirim; Emine Ozturk; Ali Aydeniz
Journal:  Clin Rheumatol       Date:  2005-10-06       Impact factor: 2.980

2.  Superolateral Hoffa's fat pad edema: association with patellofemoral maltracking and impingement.

Authors:  Ty K Subhawong; John Eng; John A Carrino; Avneesh Chhabra
Journal:  AJR Am J Roentgenol       Date:  2010-12       Impact factor: 3.959

3.  Effect of patellar taping and bracing on patellar position as determined by MRI in patients with patellofemoral pain.

Authors:  T Worrell; C D Ingersoll; K Bockrath-Pugliese; P Minis
Journal:  J Athl Train       Date:  1998-01       Impact factor: 2.860

4.  Lower extremity rotational deformities and patellofemoral alignment parameters in patients with anterior knee pain.

Authors:  Omer Faruk Erkocak; Egemen Altan; Murat Altintas; Faik Turkmen; Bahattin Kerem Aydin; Ahmet Bayar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-05-01       Impact factor: 4.342

Review 5.  Biomechanical risk factors for exercise-related lower limb injuries.

Authors:  F G Neely
Journal:  Sports Med       Date:  1998-12       Impact factor: 11.136

Review 6.  Update of Risk Factors, Diagnosis, and Management of Patellofemoral Pain.

Authors:  Daniel Sisk; Michael Fredericson
Journal:  Curr Rev Musculoskelet Med       Date:  2019-12

7.  Linear influence of distal femur osteotomy on the Q-angle: one degree of varization alters the Q-angle by one degree.

Authors:  A Flury; L Jud; A Hoch; R S Camenzind; S F Fucentese
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-09       Impact factor: 4.342

8.  Assessment of validity and reliability of femoral shaft-patellar tendon angle measured on MRI.

Authors:  Himanshu Gupta; Himanshu Kataria; Nafisa Shakir Batta; Sunil Yadav; Vineet Jain
Journal:  Skeletal Radiol       Date:  2020-10-07       Impact factor: 2.199

9.  OPTOTRAK Measurement of the Quadriceps Angle Using Standardized Foot Positions.

Authors:  Lori A Livingston; Sandi J Spaulding
Journal:  J Athl Train       Date:  2002-09       Impact factor: 2.860

10.  Relationships between lower extremity alignment and the quadriceps angle.

Authors:  Anh-Dung Nguyen; Michelle C Boling; Beverly Levine; Sandra J Shultz
Journal:  Clin J Sport Med       Date:  2009-05       Impact factor: 3.638

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.