Noninvasive continuous blood pressure measurement: a clinical evaluation of the Cortronic APM 770.

J R de Jong1, R Tepaske, G J Scheffer, H H Ros, P P Sipkema, J J de Lange.   

Abstract

The Cortronic APM 770 (Cortronic, Ronkonkoma, NY) is a commercial device that claims to measure blood pressure noninvasively and continuously with the use of a standard blood pressure cuff. The aim of our study was to assess the performance of the continuous-mode blood pressure readings of the Cortronic during anesthesia and surgery. We recorded blood pressure in 5 patients bilaterally. An interaarterial pressure (IAP) curve was recorded from 1 arm and the Cortronic pressure curve (CPC) was recorded from the other. For statistical analysis the period between 2 Cortronic recalibrations was defined as the intercalibration interval. The duration of these intervals ranged from 20 to 0.5 minutes. Four paired samples were drawn from each interval. The first sample in an interval represented the recalibration blood pressure; the other samples represented the continuous blood pressure. A total of 1,232 samples were taken, of which 308 were recalibration. The median of the differences and the 2.5th and 97.5th percentile limits of agreement were determined. Their respective values for diastolic and systolic recalibration measurements were 5, -17, and 34 mm Hg, and 6, -12, and 38 mm Hg. Their values for continuous measurements were 4, -23.5, and 32 mm Hg, and 6, -30, and 70 mm Hg. Changes in CPC were evaluated against changes in the corresponding IAP by plotting them in 4-quadrant graphs. In these graphs the Spearman rank correlations were between r = -0.17 and r = 0.01. We observed opposite CPC and IAP trends on 24 occasions during this study. We performed a simple simulation study to better understand the measurement method of the Cortronic.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8463801     DOI: 10.1007/bf01627632

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  4 in total

1.  Blood pressure monitoring: automated oscillometric devices.

Authors:  M Ramsey
Journal:  J Clin Monit       Date:  1991-01

2.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

3.  Comparative effects of captopril and isosorbide dinitrate on the arterial wall of hypertensive human brachial arteries.

Authors:  M E Safar; S Laurent; J A Bouthier; G M London
Journal:  J Cardiovasc Pharmacol       Date:  1986 Nov-Dec       Impact factor: 3.105

4.  Pulsed Doppler: determination of diameter, blood flow velocity, and volumic flow of brachial artery in man.

Authors:  J A Levenson; P A Peronneau; A Simon; M E Safar
Journal:  Cardiovasc Res       Date:  1981-03       Impact factor: 10.787

  4 in total
  1 in total

1.  Indirect blood pressure measurement using the Riva Rocci Korotkoff method.

Authors:  H H Ros
Journal:  J Clin Monit       Date:  1995-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.