Literature DB >> 6455197

Pulsed Doppler: determination of diameter, blood flow velocity, and volumic flow of brachial artery in man.

J A Levenson, P A Peronneau, A Simon, M E Safar.   

Abstract

A pulsed Doppler velocimeter suitable for the determination of blood flow velocity and volumic flow in peripheral arteries is described. The apparatus has two main characteristics: an adjustable range-gated time system and a double transducer probe. The error in the determination of the angle between the ultrasound beam and flow of blood with this apparatus was less than 2%, and overestimation of the arterial diameter due to the sample volume size did not exceed 0.035 +/- 0.015 cm. The apparatus was used to determine diameter, blood flow velocity and volumic flow of the brachial artery of 22 healthy men. The values were respectively 0.440 +/- 0.010 cm, 9.15 +/- 1.01 cm.s-1 and 85 +/- 10 cm3.min-1. Administration of intravenous nitroglycerin significantly increased the arterial diameter (p less than 0.001) without any significant change in volumic flow. The described pulsed Doppler velocimeter provides an accurate noninvasive method for determining volumic flow in peripheral arteries in clinical investigation and cardiovascular pharmacology.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 6455197     DOI: 10.1093/cvr/15.3.164

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  22 in total

1.  Acute changes in forearm haemodynamics produced by cigarette smoking in healthy normotensive non-smokers are not influenced by propranolol or pindolol.

Authors:  P Brunel; X Girerd; S Laurent; B Pannier; M Safar
Journal:  Eur J Clin Pharmacol       Date:  1992       Impact factor: 2.953

2.  Model-based assessment of dynamic arterial blood volume flow from ultrasound measurements.

Authors:  C A D Leguy; E M H Bosboom; A P G Hoeks; F N van de Vosse
Journal:  Med Biol Eng Comput       Date:  2009-03-24       Impact factor: 2.602

3.  Optimizing function and treatment of hemodialysis grafts and fistulae.

Authors:  Thomas M Vesely
Journal:  Semin Intervent Radiol       Date:  2004-06       Impact factor: 1.513

Review 4.  Heterogeneity of response of peripheral arteries to antihypertensive drugs in essential hypertension. Basic effects and functional consequences.

Authors:  J Levenson; A Simon
Journal:  Drugs       Date:  1988       Impact factor: 9.546

5.  Feasibility of dual Doppler velocity measurements to estimate volume pulsations of an arterial segment.

Authors:  Craig J Hartley; Anilkumar K Reddy; Sridhar Madala; Mark L Entman; George E Taffet
Journal:  Ultrasound Med Biol       Date:  2010-07       Impact factor: 2.998

6.  Effect of xamoterol on peripheral blood vessels in healthy subjects.

Authors:  D E Fitzgerald
Journal:  Br J Clin Pharmacol       Date:  1989       Impact factor: 4.335

7.  Transcutaneous Doppler ultrasound measurement of superior mesenteric artery blood flow in man.

Authors:  M I Qamar; A E Read; R Skidmore; J M Evans; P N Wells
Journal:  Gut       Date:  1986-01       Impact factor: 23.059

8.  Effect of morphine on the human oesophagus.

Authors:  S N Sullivan
Journal:  Gut       Date:  1986-01       Impact factor: 23.059

9.  Experience with a Doppler technique to investigate the interaction of isoprenaline and various B-adrenoceptor blocking drugs on blood vessels in the lower limb.

Authors:  D E FitzGerald; J D Harry
Journal:  Eur J Clin Pharmacol       Date:  1985       Impact factor: 2.953

10.  The use of Doppler ultrasound techniques to study the effects of isoprenaline and beta-adrenoceptor blocking drugs on peripheral blood vessels in man.

Authors:  D E Fitzgerald; J D Harry
Journal:  Br J Clin Pharmacol       Date:  1984-06       Impact factor: 4.335

View more