Literature DB >> 8457045

Randomized evaluation of pulse oximetry in 20,802 patients: II. Perioperative events and postoperative complications.

J T Moller1, N W Johannessen, K Espersen, O Ravlo, B D Pedersen, P F Jensen, N H Rasmussen, L S Rasmussen, T Pedersen, J B Cooper.   

Abstract

BACKGROUND: The authors describe the effect of pulse oximetry monitoring on the frequency of unanticipated perioperative events, changes in patient care, and the rate of postoperative complications in a prospective randomized study.
METHODS: The study included 20,802 surgical patients in Denmark randomly assigned to be monitored or not with pulse oximetry in the operating room (OR) and postanesthesia care unit (PACU).
RESULTS: During anesthesia and in the PACU, significantly more patients in the oximetry group had at least one respiratory event than did the control patients. This was the result of a 19-fold increase in the incidence of diagnosed hypoxemia in the oximetry group than in the control group in both the OR and PACU (P < 0.00001). In the OR, cardiovascular events were observed in a similar number of patients in both groups, except myocardial ischemia (as defined by angina or ST-segment depression), which was detected in 12 patients in the oximetry group and in 26 patients in the control group (P < 0.03). Several changes in PACU care were observed in association with the use of pulse oximetry. These included higher flow rate of supplemental oxygen (P < 0.00001), increased use of supplemental oxygen at discharge (P < 0.00001), and increased use of naloxone (P < 0.02). The rate of changes in patient care as a consequence of the oximetry monitoring increased as the American Society of Anesthesiologists physical status worsened (P < 0.00001). One or more postoperative complications occurred in 10% of the patients in the oximetry group and in 9.4% in the control group (difference not significant). The two groups did not differ significantly in cardiovascular, respiratory, neurologic, or infectious complications. The duration of hospital stay was a median of 5 days in both groups (difference not significant). An equal number of inhospital deaths were registered in the two groups. Questionnaires, completed by the anesthesiologists at the five participating departments, revealed that 18% of the anesthesiologists had experienced a situation in which a pulse oximeter helped to avoid a serious event or complication and that 80% of the anesthesiologists felt more secure when they used a pulse oximeter.
CONCLUSIONS: This study demonstrated that pulse oximetry can improve the anesthesiologist's ability to detect hypoxemia and related events in the OR and PACU and that the use of the oximeter was associated with a significant decrease in the rate of myocardial ischemia. Although monitoring with pulse oximetry prompted a number of changes in patient care, a reduction in the overall rate of postoperative complications was not observed.

Entities:  

Mesh:

Year:  1993        PMID: 8457045     DOI: 10.1097/00000542-199303000-00007

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  51 in total

1.  Monitoring with our good senses.

Authors:  J S Gravenstein
Journal:  J Clin Monit Comput       Date:  1998-12       Impact factor: 2.502

2.  Qualitative versus quantitative research--balancing cost, yield and feasibility. 1993.

Authors:  W B Runciman
Journal:  Qual Saf Health Care       Date:  2002-06

3.  Comparison of a prototype esophageal oximetry probe with two conventional digital pulse oximetry monitors in aortocoronary bypass patients.

Authors:  R C Prielipp; P E Scuderi; M H Hines; J L Atlee; J F Butterworth
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

4.  Isoflurane/nitrous oxide anesthesia induces increases in NMDA receptor subunit NR2B protein expression in the aged rat brain.

Authors:  Lana J Mawhinney; Juan Pablo de Rivero Vaccari; Ofelia F Alonso; Christopher A Jimenez; Concepción Furones; W Javier Moreno; Michael C Lewis; W Dalton Dietrich; Helen M Bramlett
Journal:  Brain Res       Date:  2011-11-07       Impact factor: 3.252

5.  Pro: is pulse oximetry still worthwhile?

Authors:  E C Pierce
Journal:  J Clin Monit Comput       Date:  1998-07       Impact factor: 2.502

6.  Con: is pulse oximetry still worthwhile?

Authors:  F K Orkin
Journal:  J Clin Monit Comput       Date:  1998-07       Impact factor: 2.502

7.  Influence of pulse oximeter settings on the frequency of alarms and detection of hypoxemia: Theoretical effects of artifact rejection, alarm delay, averaging, median filtering or a lower setting of the alarm limit.

Authors:  A T Rheineck-Leyssius; C J Kalkman
Journal:  J Clin Monit Comput       Date:  1998-04       Impact factor: 2.502

8.  Of Parachutes, Speedometers, and EEG: What Evidence Do We Need to Use Devices and Monitors?

Authors:  Miles Berger; Jonathan B Mark; Matthias Kreuzer
Journal:  Anesth Analg       Date:  2020-05       Impact factor: 5.108

9.  Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique.

Authors:  L Nilsson; A Johansson; S Kalman
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

10.  Estimation of jugular venous O2 saturation from cerebral oximetry or arterial O2 saturation during isocapnic hypoxia.

Authors:  M B Kim; D S Ward; C R Cartwright; J Kolano; S Chlebowski; L C Henson
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

View more