Literature DB >> 8425999

Enhanced coronary blood flow velocity during intraaortic balloon counterpulsation in critically ill patients.

M J Kern1, F V Aguirre, S Tatineni, D Penick, H Serota, T Donohue, K Walter.   

Abstract

OBJECTIVES: The aim of this study was to assess coronary blood flow during intraaortic balloon counterpulsation by direct measurement.
BACKGROUND: In a majority of human studies, increased coronary blood flow during intraaortic balloon counterpulsation measured by indirect techniques has not been consistently demonstrated.
METHODS: Hemodynamic variables and coronary blood flow velocity (20-MHz Doppler-tipped catheter) data were measured in 19 patients requiring intraaortic balloon pumping for clinical indications (11 patients had acute myocardial infarction [9 with shock], 6 had unstable angina, 1 had acute mitral regurgitation and 1 was at high risk undergoing angioplasty). Hemodynamic data, mean and phasic diastolic flow velocity and velocity-time integrals (computed from digitized waveforms) were analyzed during periods of 1:1 balloon counterpulsation.
RESULTS: Intraaortic balloon pumping decreased systolic pressure (6 +/- 10%, p < 0.001) and increased diastolic pressure (80 +/- 30% from baseline, p < 0.001) without changing RR interval. Peak phasic, mean coronary flow velocity and diastolic flow velocity integral were significantly increased (115 +/- 115%, 67 +/- 61%, 103 +/- 81%, respectively, all p < 0.001) during intraaortic balloon pumping. In addition, although a wide splay of data was evident due to operator set variations in balloon inflation and deflation timing, the greater increases in diastolic flow velocity integral (DFVi) occurred in patients with basal systolic pressure < or = 90 mm Hg (% delta DFVi = 102 - 0.1.[unaugmented systolic pressure], SEE = 21.7 mm Hg, r = 0.30, p < 0.001).
CONCLUSIONS: Intraaortic balloon pumping unequivocally and significantly augments proximal coronary blood flow velocity, nearly doubling the coronary flow velocity integral in most patients. This mechanism may be a significant means of ischemia relief in hypotensive patients.

Entities:  

Mesh:

Year:  1993        PMID: 8425999     DOI: 10.1016/0735-1097(93)90676-r

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  28 in total

1.  Cardiogenic Shock.

Authors: 
Journal:  Curr Treat Options Cardiovasc Med       Date:  2000-02

2.  Thrombolysis in Acute Myocardial Infarction Complicated by Cardiogenic Shock.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1995       Impact factor: 2.300

3.  Computational analysis of the effect of the type of LVAD flow on coronary perfusion and ventricular afterload.

Authors:  Ki Moo Lim; In Su Kim; Seong Wook Choi; Byung Goo Min; Yong Soon Won; Heon Young Kim; Eun Bo Shim
Journal:  J Physiol Sci       Date:  2009-04-23       Impact factor: 2.781

4.  IABP plus ECMO-Is one and one more than two?

Authors:  Sebastian Nuding; Karl Werdan
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

Review 5.  [Methods for coronary functional assessment].

Authors:  M Elsner
Journal:  Herz       Date:  1998-03       Impact factor: 1.443

6.  Efficacy of Subcutaneous Electrocardiogram Leads for Synchronous Timing During Chronic Counterpulsation Therapy.

Authors:  Stephen R Carnahan; Steven C Koenig; Michael A Sobieski; Erin M Schumer; Gretel Monreal; Yu Wang; Young Choi; Brek J Meuris; Landon H Tompkins; Zhongjun J Wu; Mark S Slaughter; Guruprasad A Giridharan
Journal:  ASAIO J       Date:  2017 Mar/Apr       Impact factor: 2.872

Review 7.  Continuous internal counterpulsation as a bridge to recovery in acute and chronic heart failure.

Authors:  Christos D Kontogiannis; Konstantinos Malliaras; Chris J Kapelios; Jay W Mason; John N Nanas
Journal:  World J Transplant       Date:  2016-03-24

Review 8.  How New Support Devices Change Critical Care Delivery.

Authors:  Asma Zainab; Divina Tuazon; Faisal Uddin; Iqbal Ratnani
Journal:  Methodist Debakey Cardiovasc J       Date:  2018 Apr-Jun

Review 9.  Aortic counterpulsation: C-pulse and other devices for cardiac support.

Authors:  Pallavi Solanki
Journal:  J Cardiovasc Transl Res       Date:  2014-02-20       Impact factor: 4.132

10.  Evaluation of effects of intra aortic balloon counterpulsation on autonomic nervous system functions by heart rate variability analysis.

Authors:  Ozcan Ozdemir; Omer Alyan; Fehmi Kacmaz; Zekeriya Kaptan; Cemal Ozbakir; Bilal Geyik; Goksel Cagirci; Mustafa Soylu; Ahmet Duran Demir
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-01       Impact factor: 1.468

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.