Literature DB >> 8425240

The initial distribution volume of glucose and cardiac output in the critically ill.

H Ishihara1, Y Shimodate, H Koh, K Isozaki, T Tsubo, A Matsuki.   

Abstract

Blood or plasma glucose concentration can be measured accurately and rapidly. However, after a glucose challenge metabolism may modify glucose kinetics, so that glucose has not been used as an indicator for dilution volumetry. To test the hypothesis that the initial distribution volume of glucose (IDVG) reflects cardiac output rather than glucose metabolism in the critically ill, the relationship between IDVG and thermodilution cardiac output was evaluated at 27 points in 13 non-surgical, critically ill patients without congestive heart failure. The IDVG was calculated from incremental plasma glucose concentrations using a one compartment model. Correlations were obtained between the IDVG and cardiac output (r = 0.89, n = 27, P < 0.001), and between the incremental plasma glucose concentrations three minutes after the injection and the IDVG (r = 0.94, n = 27, P < 0.001). No difference was found between the IDVG with or without continuous insulin infusions. The results indicate that the IDVG reflects cardiac output rather than glucose metabolism in patients without congestive heart failure.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8425240     DOI: 10.1007/bf03009314

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  5 in total

Review 1.  Modeling glucose metabolism in man: theory and practice.

Authors:  C Cobelli; D M Bier; E Ferrannini
Journal:  Horm Metab Res Suppl       Date:  1990

2.  Glucose space of the body.

Authors:  A N WICK; D R DRURY; E M MacKAY; N HILLYARD; R FITCH; M BLACKWELL; R W BANCROFT; M E DOROUGH
Journal:  Am J Physiol       Date:  1950-11

3.  The relationship of age to the pharmacokinetics of early drug distribution: the concurrent disposition of thiopental and indocyanine green.

Authors:  M J Avram; T C Krejcie; T K Henthorn
Journal:  Anesthesiology       Date:  1990-03       Impact factor: 7.892

Review 4.  An interpretation of the intravenous glucose tolerance test in the light of recent findings on the kinetics of glucose and insulin in man.

Authors:  V J Cunningham; D F Heath
Journal:  Clin Sci Mol Med       Date:  1978-02

5.  A pharmacokinetic analysis program (multi) for microcomputer.

Authors:  K Yamaoka; Y Tanigawara; T Nakagawa; T Uno
Journal:  J Pharmacobiodyn       Date:  1981-11
  5 in total
  11 in total

1.  Assessment of cardiac preload status by pulse pressure variation in patients after anesthesia induction: comparison with central venous pressure and initial distribution volume of glucose.

Authors:  Zhiyong He; Hui Qiao; Wei Zhou; Yun Wang; Zhendong Xu; Xuehua Che; Jun Zhang; Weimin Liang
Journal:  J Anesth       Date:  2011-09-21       Impact factor: 2.078

2.  Evaluation of fluid volume status with a glucose challenge test in a patient with acute adrenal insufficiency.

Authors:  H Ishihara; S Matsuno; S Taguchi; I Araki; T Tsubo; A Matsuki
Journal:  J Anesth       Date:  1996-03       Impact factor: 2.078

3.  Effects of cardiac output on the initial distribution volume of glucose in the absence of fluid gain or loss in pigs.

Authors:  Toshinori Kasai; Eiji Hashiba; Junichi Saito; Kazuyoshi Hirota
Journal:  J Anesth       Date:  2016-10-26       Impact factor: 2.078

4.  The initial distribution volume of glucose and cardiac output after haemorrhage in dogs.

Authors:  Y Shimodate; H Ishihara; A Matsuki
Journal:  Can J Anaesth       Date:  1994-03       Impact factor: 5.063

5.  Estimation of the initial distribution volume of glucose by an incremental plasma glucose level at 3 min after i.v. glucose in humans.

Authors:  K Hirota; H Ishihara; T Tsubo; A Matsuki
Journal:  Br J Clin Pharmacol       Date:  1999-04       Impact factor: 4.335

6.  Corrected right ventricular end-diastolic volume and initial distribution volume of glucose correlate with cardiac output after cardiac surgery.

Authors:  Junichi Saito; Hironori Ishihara; Eiji Hashiba; Hirobumi Okawa; Tomoyuki Kudo; Masahiro Sawada; Toshihito Tsubo; Kazuyoshi Hirota
Journal:  J Anesth       Date:  2013-03-02       Impact factor: 2.078

7.  Does the initial distribution volume of glucose reflect plasma volume after haemorrhage in dogs?

Authors:  H Koh; H Ishihara; A Miyahara; S Takahashi; A Matsuki
Journal:  Can J Anaesth       Date:  1995-02       Impact factor: 5.063

Review 8.  Haemodynamic monitoring in acute heart failure.

Authors:  Maurizio Cecconi; Toby E Reynolds; Nawaf Al-Subaie; Andrew Rhodes
Journal:  Heart Fail Rev       Date:  2007-06       Impact factor: 4.214

9.  Initial distribution volume of glucose can be approximated using a conventional glucose analyzer in the intensive care unit.

Authors:  Hironori Ishihara; Hitomi Nakamura; Hirobumi Okawa; Hajime Takase; Toshihito Tsubo; Kazuyoshi Hirota
Journal:  Crit Care       Date:  2005-02-11       Impact factor: 9.097

10.  Blood glucose increments as a measure of body physiology.

Authors:  Robert G Hahn
Journal:  Crit Care       Date:  2005-02-28       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.