Portable chest imaging: comparison of storage phosphor digital, asymmetric screen-film, and conventional screen-film systems.

L T Niklason1, H P Chan, P N Cascade, C L Chang, P W Chee, J F Mathews.   

Abstract

The quality of chest images obtained with portable radiography was evaluated for a conventional screen-film system, a new asymmetric screen-film chest system, and computed radiography (CR). Sixty chest images were obtained in 20 patients in an intensive care unit. The CR system was ranked by all three evaluating radiologists as substantially better in overall diagnostic quality, interpretability of the lungs, and musculoskeletal detail and by two of the three observers as better for the visibility of catheters and lines. In the upper abdomen and mediastinum, there was not a clear preference. Standard deviations of film density were +/- 0.12, +/- 0.41, and +/- 0.39 for the CR, conventional, and asymmetric systems, respectively. For the same systems, phantom results indicated the relative lung contrast values were 1.2, 1.0, and 0.89, respectively. Similarly, the limiting resolution values in the lung were 2.0, 4.2, and 6.3 line pairs per millimeter. The CR system had twice the root-mean-square noise of the screen-film systems. Overall, the preferred system for portable chest imaging was the CR system.

Entities:  

Mesh:

Year:  1993        PMID: 8421740     DOI: 10.1148/radiology.186.2.8421740

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  9 in total

1.  Computed radiography dual energy subtraction: performance evaluation when detecting low-contrast lung nodules in an anthropomorphic phantom.

Authors:  C Kimme-Smith; D L Davis; M McNitt-Gray; J Goldin; E Hart; P Batra; T D Johnson
Journal:  J Digit Imaging       Date:  1999-02       Impact factor: 4.056

2.  A cost-analysis of computed radiography and picture archiving and communication systems in portable radiography.

Authors:  W Huda; J C Honeyman; M M Frost; E V Staab
Journal:  J Digit Imaging       Date:  1996-02       Impact factor: 4.056

3.  Current status of computed radiography in emergency departments.

Authors:  W Huda; D A Smith; E V Staab
Journal:  J Digit Imaging       Date:  1997-11       Impact factor: 4.056

4.  Support line and tube visibility in chest examinations using computed radiography.

Authors:  W Huda; C J Belden; L A Webb; C K Palmer
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

5.  Evaluation of a noise reduction procedure for chest radiography.

Authors:  Ryohei Fukui; Rie Ishii; Kazuhiko Kodani; Yoshiko Kanasaki; Hisashi Suyama; Masanari Watanabe; Masaki Nakamoto; Yasushi Fukuoka
Journal:  Yonago Acta Med       Date:  2013-11-28       Impact factor: 1.641

6.  Digital chest radiography: clinical aspects.

Authors:  U Tylén
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

7.  Development of a digital duplication system for portable chest radiographs.

Authors:  K R Hoffmann; K Doi; H MacMahon; M L Giger; R M Nishikawa; X W Xu; L Yao; A Kano; M Carlin
Journal:  J Digit Imaging       Date:  1994-08       Impact factor: 4.056

8.  Clinical evaluation of irreversible data compression for computed radiography of the chest.

Authors:  K Egashira; H Nakata; H Watanabe; K Uchida; K Nakamura; Y Ishino; K Horino; R Yoshikawa
Journal:  J Digit Imaging       Date:  1998-11       Impact factor: 4.056

9.  Efficiency and reporting confidence analysis of sequential dual-energy subtraction for thoracic x-ray examinations.

Authors:  Mehmet Can Gezer; Oktay Algin; Aytac Durmaz; Halil Arslan
Journal:  Qatar Med J       Date:  2019-09-23
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.