The effect of source size on the buildup factor calculation of absolute volume.

J A Siegel.   

Abstract

A general scheme for generating attenuation-corrected images for use in absolute volume measurements has been developed. The technique is based on a buildup factor approach for Compton scatter compensation and requires anterior and posterior count-rate measurements. The scatter correction requires evaluation of the attenuation factor (1-(1-e-mu d)B(infinity), where mu is the linear attenuation coefficient in cm-1 and B(infinity) is the buildup factor at infinite depth. The attenuation factors for four different source sizes using 99mTcO4- and a 20% scintillation camera energy window are reported. The results indicated that B(infinity) was constant while mu varied as a function of size (S) in pixels according to mu = 0.151 cm-1 X exp(-1.18 X 10(-4) pixels-1 X S). Once the appropriate value of mu was determined, a pair of anterior-posterior count rate equations was used to generate attenuation-corrected count rate data for use in absolute volume measurements. The method was validated by calculating three separate phantom volumes. The results showed that the method provides less than +/- 6.0% error for volume determinations at all investigated depths.

Entities:  

Mesh:

Year:  1985        PMID: 4056928

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  6 in total

1.  Quantitative renography with the organ volume method and interporative background subtraction technique.

Authors:  A Kojima; Y Takaki; A Tsuji; R Nakashima; M Kira; M Hara; S Tomiguchi; M Matsumoto; M Takahashi
Journal:  Ann Nucl Med       Date:  1996-11       Impact factor: 2.668

2.  Biphasic nature of gastric emptying.

Authors:  J A Siegel; J L Urbain; L P Adler; N D Charkes; A H Maurer; B Krevsky; L C Knight; R S Fisher; L S Malmud
Journal:  Gut       Date:  1988-01       Impact factor: 23.059

3.  The two-component stomach: effects of meal particle size on fundal and antral emptying.

Authors:  J L Urbain; J A Siegel; N D Charkes; A H Maurer; L S Malmud; R S Fisher
Journal:  Eur J Nucl Med       Date:  1989

4.  Quantification of technetium-99m lung radioactivity from planar images.

Authors:  N I Forge; P J Mountford; M J O'Doherty
Journal:  Eur J Nucl Med       Date:  1993-01

Review 5.  Aerosols for therapy and diagnosis.

Authors:  M J O'Doherty; R F Miller
Journal:  Eur J Nucl Med       Date:  1993-12

6.  Evaluation of (123)I-orthoiodohippurate single kidney clearance rate by renal sequential scintigraphy in a large cohort of likely normal subjects aged between 0 and 18 years.

Authors:  Alessio Imperiale; Catia Olianti; Giannetto Comis; Giuseppe La Cava
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-28       Impact factor: 10.057