Literature DB >> 1662583

Variability in the measurement of nebulized aerosol deposition in man.

S H Thomas1, M J O'Doherty, C J Page, T O Nunan.   

Abstract

1. This study was performed to determine the variability of two different scintigraphic methods of measuring pulmonary aerosol deposition, and to examine nebulizer particle size and drug output as potential sources of this variability. 2. A radioaerosol was produced from a 3 ml solution of 99mTc-labelled colloidal human serum albumin (0.05 mg, 37 MBq) using a standard jet nebulizer and air compressor. This was inhaled on three separate occasions by nine healthy male subjects. One one of these occasions, a further inhalation was performed to assess immediate repeatability using increased 99mTc activity (92 MBq). 3. Intrapulmonary aerosol deposition was measured with a gamma-camera and was corrected for tissue attenuation and geometric distribution by using two different methods. 4. Estimated mean pulmonary deposition was 4.3% of the nebulizer dose using a lung phantom correction method, and 6.1% using a tissue attenuation method. For these two methods respectively variability between subjects (coefficient of variation) was 54 and 47%. For both methods, within-subject variability (coefficient of variation) was 37% between occasions and 23% within occasions. 5. The particle-size output of several nebulizers was highly reproducible (coefficient of variation less than 4%), but the nebulizer mass and radionuclide output of two nebulizers was more variable (coefficient of variation 5-19%), and appeared to be an important contributor to the variability in pulmonary aerosol deposition. 6. The data presented here for pulmonary deposition, used with appropriate power statistics formulae, can be used to estimate the sample sizes required for comparative studies of lung aerosol deposition.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1662583     DOI: 10.1042/cs0810767

Source DB:  PubMed          Journal:  Clin Sci (Lond)        ISSN: 0143-5221            Impact factor:   6.124


  11 in total

1.  SPECT-CT Comparison of Lung Deposition using a System combining a Vibrating-mesh Nebulizer with a Valved Holding Chamber and a Conventional Jet Nebulizer: a Randomized Cross-over Study.

Authors:  Jonathan Dugernier; Michel Hesse; Rita Vanbever; Virginie Depoortere; Jean Roeseler; Jean-Bernard Michotte; Pierre-François Laterre; François Jamar; Gregory Reychler
Journal:  Pharm Res       Date:  2016-11-07       Impact factor: 4.200

2.  Quantification of technetium-99m lung radioactivity from planar images.

Authors:  N I Forge; P J Mountford; M J O'Doherty
Journal:  Eur J Nucl Med       Date:  1993-01

Review 3.  Aerosols for therapy and diagnosis.

Authors:  M J O'Doherty; R F Miller
Journal:  Eur J Nucl Med       Date:  1993-12

Review 4.  Studies using radiolabelled aerosols in children.

Authors:  M L Everard
Journal:  Thorax       Date:  1994-12       Impact factor: 9.139

5.  Lung deposition of nebulised pentamidine in children.

Authors:  M J O'Doherty; S H Thomas; D Gibb; C J Page; C Harrington; C Duggan; T O Nunan; N T Bateman
Journal:  Thorax       Date:  1993-03       Impact factor: 9.139

6.  Therapeutic aerosols in children.

Authors:  S H Thomas; S Batchelor; M J O'Doherty
Journal:  BMJ       Date:  1993-07-24

7.  Effect of two administration routes of Shenmai Injection () on pulmonary gas exchange function after tourniquet-induced ischemia-reperfusion.

Authors:  Jian-Guo Jin; Hai-Jian Shen; Yuan-Lu Shan; Lei Chen; Xi-Yue Zhao; Liang-Rong Wang; Li-Na Lin
Journal:  Chin J Integr Med       Date:  2016-06-14       Impact factor: 1.978

8.  Pulmonary deposition of aerosolised pentamidine using a new nebuliser: efficiency measurements in vitro and in vivo.

Authors:  P P Ferretti; A Versari; S I Gafà; M H Becquemin; E Barchi; D Serafini; M Roy; D Salvo; A Bouchikhi
Journal:  Eur J Nucl Med       Date:  1994-05

9.  Lack of effect of inhaled morphine on exercise-induced breathlessness in chronic obstructive pulmonary disease.

Authors:  A R Masood; J W Reed; S H Thomas
Journal:  Thorax       Date:  1995-06       Impact factor: 9.139

10.  Aerosol delivery with two ventilation modes during mechanical ventilation: a randomized study.

Authors:  Jonathan Dugernier; Gregory Reychler; Xavier Wittebole; Jean Roeseler; Virginie Depoortere; Thierry Sottiaux; Jean-Bernard Michotte; Rita Vanbever; Thierry Dugernier; Pierre Goffette; Marie-Agnes Docquier; Christian Raftopoulos; Philippe Hantson; François Jamar; Pierre-François Laterre
Journal:  Ann Intensive Care       Date:  2016-07-22       Impact factor: 6.925

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.