Literature DB >> 8412557

Hemodynamic assessment in managing the critically ill: is physician confidence warranted?

N V Dawson1, A F Connors, T Speroff, A Kemka, P Shaw, H R Arkes.   

Abstract

Prior to right-heart catheterization of 846 patients, 198 study physicians estimated values of pulmonary capillary wedge pressure (WP), cardiac index (Cl), and systemic vascular resistance index (VRI). The physicians also expressed their confidence in these estimates. Actual values of WP, Cl, and VRI as determined by catheterization enabled the authors to evaluate the quality of the physicians' judgments. The discrimination of the judgments was modest; areas under the ROC curves for WP, Cl, and VRI were 0.724, 0.681, and 0.656, respectively. Calculated using clinically relevant cutoff values, sensitivities were 64%, 50%, and 64%, and specificities were 71%, 75%, and 63%, respectively. Calibration of the estimates of WP, Cl, and VRI was also modest; physicians tended to overestimate low values and underestimate high values. Physicians were generally confident of their estimates, but there was no relation between confidence and accuracy. Experienced physicians were no more accurate than less experienced ones, although they were significantly more confident. The authors conclude that physicians should not use their levels of confidence in their subjective estimates of cardiac function in deciding whether to base therapy on these estimates.

Entities:  

Mesh:

Year:  1993        PMID: 8412557     DOI: 10.1177/0272989X9301300314

Source DB:  PubMed          Journal:  Med Decis Making        ISSN: 0272-989X            Impact factor:   2.583


  11 in total

1.  Pre-operative diagnostic radiograph interpretation by general dental practitioners for root canal treatment.

Authors:  I Anand Sherwood
Journal:  Dentomaxillofac Radiol       Date:  2011-11-10       Impact factor: 2.419

2.  The effects of advanced monitoring on hemodynamic management in critically ill patients: a pre and post questionnaire study.

Authors:  Azriel Perel; Bernd Saugel; Jean-Louis Teboul; Manu L N G Malbrain; Francisco Javier Belda; Enrique Fernández-Mondéjar; Mikhail Kirov; Julia Wendon; Roger Lussmann; Marco Maggiorini
Journal:  J Clin Monit Comput       Date:  2015-12-10       Impact factor: 2.502

3.  Awareness of the Food and Drug Administration's Bad Ad Program and Education Regarding Pharmaceutical Advertising: A National Survey of Prescribers in Ambulatory Care Settings.

Authors:  Amie C O'Donoghue; Vanessa Boudewyns; Kathryn J Aikin; Emily Geisen; Kevin R Betts; Brian G Southwell
Journal:  J Health Commun       Date:  2015-07-15

Review 4.  Strategies for Improving Learner Metacognition in Health Professional Education.

Authors:  Melissa S Medina; Ashley N Castleberry; Adam M Persky
Journal:  Am J Pharm Educ       Date:  2017-05       Impact factor: 2.047

5.  Clinical examination: a trigger but not a substitute for hemodynamic evaluation.

Authors:  Daniel De Backer; Antoine Vieillard-Baron
Journal:  Intensive Care Med       Date:  2019-01-24       Impact factor: 17.440

6.  Early hemodynamic assessment and treatment of elderly patients in the medical ICU.

Authors:  Gorazd Voga; Lucija Gabršček-Parežnik
Journal:  Wien Klin Wochenschr       Date:  2016-11-28       Impact factor: 1.704

7.  Are residents' decisions influenced more by a decision aid or a specialist's opinion? A randomized controlled trial.

Authors:  Mitchell A Medow; Hal R Arkes; Victoria A Shaffer
Journal:  J Gen Intern Med       Date:  2010-01-30       Impact factor: 5.128

8.  Patients' prerogatives and perceptions of benefit.

Authors:  F Kee
Journal:  BMJ       Date:  1996-04-13

Review 9.  Clinical examination for diagnosing circulatory shock.

Authors:  Bart Hiemstra; Ruben J Eck; Frederik Keus; Iwan C C van der Horst
Journal:  Curr Opin Crit Care       Date:  2017-08       Impact factor: 3.687

10.  Pulmonary artery occlusion pressure estimation by transesophageal echocardiography: is simpler better?

Authors:  Gorazd Voga
Journal:  Crit Care       Date:  2008-03-31       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.