| Literature DB >> 8403646 |
R Kdolsky1, O Kwasny, R Schabus.
Abstract
The long-term results (five-to eight-year follow-up evaluation) of 66 patients with high proximal ruptures of the anterior cruciate ligament (ACL) who were treated operatively are presented in a retrospective and uncontrolled study. Technique of surgery was the reinsertion of the ACL in a multiple suture loop technique, augmented with Kennedy-LAD (ligament augmentation device) on over the top route in temporary double-end fixation. This technique was used in patients with proximal rupture of the anterior cruciate ligament found at arthroscopy. In the follow-up as well as in instrumented measurement, 97% of the knee joints have normal joint laxity. According to the evaluation sheet designed by the Orthopädische Arbeitsgemeinschaft Knie (OAK), excellent or good results were found in 86% of the patients. Nine percent had limited range of motion. The ACL reconstruction technique allowed 75% of the patients to regain their preinjury sports activity level. The potential advantages of synthetic augmented reinsertion of the ACL are anatomic reconstruction without destruction of other anatomic structures as grafts; securing early rehabilitation with weight bearing of the operated limb depending on individual pain tolerance; and presenting excellent long-term results of normal joint laxity.Entities:
Mesh:
Year: 1993 PMID: 8403646
Source DB: PubMed Journal: Clin Orthop Relat Res ISSN: 0009-921X Impact factor: 4.176