Literature DB >> 8400569

Reduction of ringing and blurring artifacts in fast spin-echo imaging.

X Zhou1, Z P Liang, G P Cofer, C F Beaulieu, S A Suddarth, G A Johnson.   

Abstract

A simple method was devised to reduce ringing and blurring artifacts caused by discontinuous T2 weighting of k-space data in fast spin-echo magnetic resonance (MR) imaging. The method demodulates the weighting function along the phase-encoding direction by using multiple T2 values derived from a set of non-phase-encoded echoes obtained from an extra excitation. The performance of this method was evaluated by computer simulations and experiments, which confirmed its capability of effectively reducing or, in some cases, even completely removing the ringing and blurring artifacts. The results also show that the proposed method produces better results than other artifact reduction methods. The method is particularly useful at high magnetic field strengths (7.1-9.4 T) and with strong gradients (> 20 G/cm) used in MR microscopy, in which the apparent T2 values are short for most tissues. The authors expect that the proposed method will find useful applications in various fast spin-echo pulse sequences.

Mesh:

Year:  1993        PMID: 8400569     DOI: 10.1002/jmri.1880030518

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  10 in total

1.  Reduction of artifacts in T2 -weighted PROPELLER in high-field preclinical imaging.

Authors:  Prachi Pandit; Yi Qi; Kevin F King; G Allan Johnson
Journal:  Magn Reson Med       Date:  2010-10-06       Impact factor: 4.668

2.  Controlling T2 blurring in 3D RARE arterial spin labeling acquisition through optimal combination of variable flip angles and k-space filtering.

Authors:  Li Zhao; Ching-Di Chang; David C Alsop
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

3.  T2 shuffling: Sharp, multicontrast, volumetric fast spin-echo imaging.

Authors:  Jonathan I Tamir; Martin Uecker; Weitian Chen; Peng Lai; Marcus T Alley; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2016-01-20       Impact factor: 4.668

4.  Incorporating relaxivities to more accurately reconstruct MR images.

Authors:  Muge Karaman; Iain P Bruce; Daniel B Rowe
Journal:  Magn Reson Imaging       Date:  2015-01-15       Impact factor: 2.546

5.  Signal compensation and compressed sensing for magnetization-prepared MR angiography.

Authors:  Tolga Çukur; Michael Lustig; Emine U Saritas; Dwight G Nishimura
Journal:  IEEE Trans Med Imaging       Date:  2011-02-17       Impact factor: 10.048

6.  Steer-PROP: a GRASE-PROPELLER sequence with interecho steering gradient pulses.

Authors:  Girish Srinivasan; Novena Rangwala; Xiaohong Joe Zhou
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

7.  Visualization of Human Aortic Valve Dynamics Using Magnetic Resonance Imaging with Sub-Millisecond Temporal Resolution.

Authors:  Zheng Zhong; Kaibao Sun; Guangyu Dan; Qingfei Luo; Afshin Farzaneh-Far; Meryem Muge Karaman; Xiaohong Joe Zhou
Journal:  J Magn Reson Imaging       Date:  2021-03-24       Impact factor: 5.119

8.  SPRING-RIO TSE: 2D T2 -Weighted Turbo Spin-Echo brain imaging using SPiral RINGs with retraced in/out trajectories.

Authors:  Zhixing Wang; Steven P Allen; Xue Feng; John P Mugler; Craig H Meyer
Journal:  Magn Reson Med       Date:  2022-04-08       Impact factor: 3.737

9.  Magnetic resonance imaging with submillisecond temporal resolution.

Authors:  Zheng Zhong; Kaibao Sun; M Muge Karaman; Xiaohong Joe Zhou
Journal:  Magn Reson Med       Date:  2020-11-30       Impact factor: 3.737

10.  Prospective acceleration of diffusion tensor imaging with compressed sensing using adaptive dictionaries.

Authors:  Darryl McClymont; Irvin Teh; Hannah J Whittington; Vicente Grau; Jürgen E Schneider
Journal:  Magn Reson Med       Date:  2015-08-24       Impact factor: 4.668

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.