Literature DB >> 8356130

Definitive diagnosis of breast implant rupture using magnetic resonance imaging.

C Y Ahn1, W W Shaw, K Narayanan, D P Gorczyca, S Sinha, N D Debruhl, L W Bassett.   

Abstract

Breast implant rupture is an important complication of augmented and reconstructed breasts. Although several techniques such as mammography, xeromammography, ultrasound, thermography, and computed tomographic (CT) scanning have been proven to be useful to detect implant rupture, they have several disadvantages and lack specificity. In the current study, we have established magnetic resonance imaging (MRI) as a definitive, reliable, and reproducible technique to diagnose both intracapsular and extracapsular ruptures. The study was conducted in 100 symptomatic patients. Our imaging parameters were able to identify ruptures in implants with silicone shells. All the ruptures showed the presence of wavy lines, free-floating silicone shell within the gel ("free-floating loose-thread sign" or "linguine sign"). We had a 3.75 percent incidence of false-positive and false-negative results. The sensitivity for detection of silicone implant rupture was 76 percent, with a specificity of 97 percent. In addition, we also were able to identify the artifacts that may interfere with the definitive diagnosis of implant rupture.

Entities:  

Mesh:

Year:  1993        PMID: 8356130     DOI: 10.1097/00006534-199309001-00018

Source DB:  PubMed          Journal:  Plast Reconstr Surg        ISSN: 0032-1052            Impact factor:   4.730


  5 in total

1.  Study of breast implant rupture: MRI versus surgical findings.

Authors:  A Vestito; F F Mangieri; A Ancona; C Minervini; V Perchinunno; S Rinaldi
Journal:  Radiol Med       Date:  2012-03-19       Impact factor: 3.469

2.  MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard.

Authors:  M C Maijers; F B Niessen; J F H Veldhuizen; M J P F Ritt; R A Manoliu
Journal:  Eur Radiol       Date:  2014-03-06       Impact factor: 5.315

Review 3.  State of the art of current modalities for the diagnosis of breast lesions.

Authors:  Cosimo Di Maggio
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-04-15       Impact factor: 9.236

4.  Dual-energy CT for the evaluation of silicone breast implants.

Authors:  Thorsten R C Johnson; Isabelle Himsl; Karin Hellerhoff; Doris Mayr; Dorothea Rjosk-Dendorfer; Nina Ditsch; Bernhard Krauss; Klaus Friese; Maximilian F Reiser; Miriam S Lenhard
Journal:  Eur Radiol       Date:  2012-10-13       Impact factor: 5.315

5.  Endoscopic plastic surgery: the endoscopic evaluation of implants after breast augmentation.

Authors:  G M Beer; P Kompatscher
Journal:  Aesthetic Plast Surg       Date:  1995 Jul-Aug       Impact factor: 2.326

  5 in total