Literature DB >> 8354230

Fast analysis of proteins by isoelectric focusing performed in capillary array detected with concentration gradient imaging system.

J Wu1, J Pawliszyn.   

Abstract

Isoelectric focusing of several protein samples is performed simultaneously in an array of 2-4 short capillaries (4-10 cm long). The separated proteins are detected by either an on-line concentration gradient imaging detection system, or a single point concentration gradient detector which requires a mobilization step following the focusing process. The application of the capillary array increases the throughput of the capillary isoelectric focusing (CIEF) technique, and makes the technique comparable in sample throughput to the gel slab isoelectric focusing technique, but with much faster speed of separation and quantitation. The analysis is completed in 2-3 min with the imaging detection system, which is about 100 times faster than the conventional gel slab isoelectric focusing and 10 times faster compared to conventional CIEF. The resolution of the separation is 0.02 pH units or better. All separated proteins in the capillary array are detected by the universal concentration gradient detector, which eliminates the need for sample derivatization. The concentration limit of detection for the inexpensive instrument described in this work is about 30 micrograms/mL and can be reduced by using higher quality components in the system, such as a more stable laser, higher optical quality capillaries and a faster computer A/D board. The sample consumption is 400 nL for the 4 cm long, 100 microns ID square capillary. The isoelectric point (pI) values of the samples can be directly determined without internal pI markers from their positions inside the capillary after focusing when the imaging detection system is used.

Mesh:

Substances:

Year:  1993        PMID: 8354230     DOI: 10.1002/elps.1150140172

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

Review 1.  Clinical applications of capillary electrophoresis. Status at the new millennium.

Authors:  M A Jenkins
Journal:  Mol Biotechnol       Date:  2000-07       Impact factor: 2.695

2.  Capillary array isoelectric focusing with laser-induced fluorescence detection: milli-pH unit resolution and yoctomole mass detection limits in a 32-channel system.

Authors:  Oluwatosin O Dada; Lauren M Ramsay; Jane A Dickerson; Nathan Cermak; Rong Jiang; Cuiru Zhu; Norman J Dovichi
Journal:  Anal Bioanal Chem       Date:  2010-03-25       Impact factor: 4.142

3.  Capillary isoelectric focusing with pH 9.7 cathode for the analysis of gastric biopsies.

Authors:  Lauren M Ramsay; Nathan Cermak; Oluwatosin O Dada; Norman J Dovichi
Journal:  Anal Bioanal Chem       Date:  2011-04-02       Impact factor: 4.142

4.  Field-free remobilization of proteins after isoelectric focusing in packed capillaries.

Authors:  Yimin Hua; Brooke M Koshel; Mary J Wirth
Journal:  Anal Chem       Date:  2010-10-08       Impact factor: 6.986

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.