Literature DB >> 8347951

Noise reduction in three-dimensional phase-contrast MR velocity measurements.

S M Song1, S Napel, G H Glover, N J Pelc.   

Abstract

The authors have developed a method to reduce noise in three-dimensional (3D) phase-contrast magnetic resonance (MR) velocity measurements by exploiting the property that blood is incompressible and, therefore, the velocity field describing its flow must be divergence-free. The divergence-free condition is incorporated by a projection operation in Hilbert space. The velocity field obtained with 3D phase-contrast MR imaging is projected onto the space of divergence-free velocity fields. The reduction of noise is achieved because the projection operation eliminates the noise component that is not divergence-free. Signal-to-noise ratio (S/N) gains on the order of 15%-25% were observed. The immediate effect of this noise reduction manifests itself in higher-quality phase-contrast MR angiograms. Alternatively, the S/N gain can be traded for a reduction in imaging time and/or improved spatial resolution.

Mesh:

Year:  1993        PMID: 8347951     DOI: 10.1002/jmri.1880030407

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  8 in total

1.  Vector-field classification in magnetic-resonance angiography.

Authors:  M A Tovar
Journal:  Proc AMIA Symp       Date:  1998

2.  Merging computational fluid dynamics and 4D Flow MRI using proper orthogonal decomposition and ridge regression.

Authors:  Ali Bakhshinejad; Ahmadreza Baghaie; Alireza Vali; David Saloner; Vitaliy L Rayz; Roshan M D'Souza
Journal:  J Biomech       Date:  2017-05-17       Impact factor: 2.712

3.  Virtual injections using 4D flow MRI with displacement corrections and constrained probabilistic streamlines.

Authors:  Grant S Roberts; Michael W Loecher; Alma Spahic; Kevin M Johnson; Patrick A Turski; Laura B Eisenmenger; Oliver Wieben
Journal:  Magn Reson Med       Date:  2021-12-31       Impact factor: 4.668

4.  Robust 4D flow denoising using divergence-free wavelet transform.

Authors:  Frank Ong; Martin Uecker; Umar Tariq; Albert Hsiao; Marcus T Alley; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-02-18       Impact factor: 4.668

5.  Hemolytic Performance in Two Generations of the Sputnik Left Ventricular Assist Device: A Combined Numerical and Experimental Study.

Authors:  Alexandra N Romanova; Alexander A Pugovkin; Maxim V Denisov; Ivan A Ephimov; Dmitry V Gusev; Marian Walter; Thomas Groth; Olga L Bockeria; Tatyana G Le; Anna S Satyukova; Sergey V Selishchev; Dmitry V Telyshev
Journal:  J Funct Biomater       Date:  2022-01-12

Review 6.  Cardiovascular magnetic resonance phase contrast imaging.

Authors:  Krishna S Nayak; Jon-Fredrik Nielsen; Matt A Bernstein; Michael Markl; Peter D Gatehouse; Rene M Botnar; David Saloner; Christine Lorenz; Han Wen; Bob S Hu; Frederick H Epstein; John N Oshinski; Subha V Raman
Journal:  J Cardiovasc Magn Reson       Date:  2015-08-09       Impact factor: 5.364

7.  Computational fluid dynamics simulations of blood flow regularized by 3D phase contrast MRI.

Authors:  Vinicius C Rispoli; Jon F Nielsen; Krishna S Nayak; Joao L A Carvalho
Journal:  Biomed Eng Online       Date:  2015-11-26       Impact factor: 2.819

8.  Comparison of direct and inverse methods for 2.5D traction force microscopy.

Authors:  Johannes W Blumberg; Ulrich S Schwarz
Journal:  PLoS One       Date:  2022-01-20       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.