Literature DB >> 8339732

Improved detection of a staphylococcal infection by monomeric and protein A-purified polyclonal human immunoglobulin.

W Calame1, M Welling, H I Feitsma, G J Ensing, E K Pauwels.   

Abstract

The present study was undertaken to compare the technetium-99m labelled non-specific polyclonal human immunoglobulin (Ig) with 99mTc-labelled monomeric human immunoglobulin (m-Ig), 99mTc-labelled, protein A-purified, human immunoglobulin (A-Ig) and 99mTc-labelled monomeric, protein A-purified, human immunoglobulin (mA-Ig) as tracer agents for the detection of a thigh infection with Staphylococcus aureus. In vitro the binding of the various tracer agents to bacteria at various intervals was determined. For the in vivo evaluation, mice were infected and received one of the various labelled proteins. Scintigrams were made 0.25, 1, 4 and 24 h later. All 99mTc-labelled Igs bound to bacteria in vitro: the percentages of binding for the m-Ig (from 1 h onwards) and A-Ig and mA-Ig (from 3 h onwards) were significantly higher than that for Ig. The in vivo target-to-non-target (T/NT) ratios were significantly higher from 4 h onwards for all purified Igs than for Ig. Protein A-purified Igs yielded higher T/NT ratios than m-Ig. Furthermore, the amount of activity in the liver was significantly lower 24 h after administration of m-Ig, A-Ig and mA-Ig than after administration of Ig. It is concluded that in this experimental infection 99mTc-labelled monomeric Ig localizes a staphylococcal thigh infection better and faster than 99mTc-labelled unpurified Ig. However, the accumulation obtained with protein A-purified Ig or protein A-purified monomeric Ig was the highest of all tracer agents tested.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8339732     DOI: 10.1007/bf00175161

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  15 in total

Review 1.  Quo vadis radioimmune imaging.

Authors:  A J Fischman; B A Khaw; H W Strauss
Journal:  J Nucl Med       Date:  1989-11       Impact factor: 10.057

2.  Binding of 99mTc-labelled polyclonal human immunoglobulin to bacteria as a mechanism for scintigraphic detection of infection.

Authors:  W Calame; H I Feitsma; G J Ensing; J W Arndt; R van Furth; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1991

3.  Isolation of pure IgG1, IgG2a and IgG2b immunoglobulins from mouse serum using protein A-sepharose.

Authors:  P L Ey; S J Prowse; C R Jenkin
Journal:  Immunochemistry       Date:  1978-07

4.  99mTc-human immunoglobulin (HIG)--first results of a new agent for the localization of infection and inflammation.

Authors:  J R Buscombe; D Lui; G Ensing; R de Jong; P J Ell
Journal:  Eur J Nucl Med       Date:  1990

5.  Imaging focal sites of bacterial infection in rats with indium-111-labeled chemotactic peptide analogs.

Authors:  A J Fischman; M C Pike; D Kroon; A J Fucello; D Rexinger; C ten Kate; R Wilkinson; R H Rubin; H W Strauss
Journal:  J Nucl Med       Date:  1991-03       Impact factor: 10.057

6.  Autoradiographic method for quantitation of radiolabeled proteins in tissues using indium-111.

Authors:  E M Morrell; R G Tompkins; A J Fischman; R A Wilkinson; J F Burke; R H Rubin; H W Strauss; M L Yarmush
Journal:  J Nucl Med       Date:  1989-09       Impact factor: 10.057

7.  99mTc-labelled polyclonal human immunoglobulin for localization of inflammatory sites--early in vitro-results.

Authors:  A Saptogino; W Becker; F Wolf
Journal:  Nuklearmedizin       Date:  1990-03       Impact factor: 1.379

8.  Scintigraphic detection of bone and joint infections with indium-111-labeled nonspecific polyclonal human immunoglobulin G.

Authors:  W J Oyen; R A Claessens; J R van Horn; J W van der Meer; F H Corstens
Journal:  J Nucl Med       Date:  1990-04       Impact factor: 10.057

9.  Influence of etoposide and cyclophosphamide on the efficacy of cloxacillin and erythromycin in an experimental staphylococcal infection.

Authors:  W Calame; R van der Waals; H Mattie; R van Furth
Journal:  Antimicrob Agents Chemother       Date:  1989-06       Impact factor: 5.191

10.  Detection of acute inflammation with 111In-labeled nonspecific polyclonal IgG.

Authors:  A J Fischman; R H Rubin; B A Khaw; R J Callahan; R Wilkinson; F Keech; M Nedelman; S Dragotakes; P B Kramer; G M LaMuraglia
Journal:  Semin Nucl Med       Date:  1988-10       Impact factor: 4.446

View more
  4 in total

Review 1.  The uptake mechanisms of inflammation- and infection-localizing agents.

Authors:  W J Oyen; O C Boerman; C J van der Laken; R A Claessens; J W van der Meer; F H Corstens
Journal:  Eur J Nucl Med       Date:  1996-04

2.  Optimized localization of bacterial infections with technetium-99m labelled human immunoglobulin after protein charge selection.

Authors:  M Welling; H I Feitsma; W Calame; G J Ensing; W Goedemans; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1994-10

3.  Contribution of phagocytic cells and bacteria to the accumulation of technetium-99m labelled polyclonal human immunoglobulin at sites of inflammation.

Authors:  W Calame; M Welling; H I Feitsma; W T Goedemans; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1995-07

4.  Technetium-99m Tricarbonyl Labeled a Broad-spectrum Quinolone as a Specific Imaging Agent in Infection Diseases.

Authors:  Seyed Javad Khoramrouz; Mostafa Erfani; Mitra Athari Allaf
Journal:  Iran J Pharm Res       Date:  2017       Impact factor: 1.696

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.