Literature DB >> 2324817

Scintigraphic detection of bone and joint infections with indium-111-labeled nonspecific polyclonal human immunoglobulin G.

W J Oyen1, R A Claessens, J R van Horn, J W van der Meer, F H Corstens.   

Abstract

The utility of indium-111-(111In) labeled immunoglobulin G (IgG) to detect infection of bone and adjacent tissues was investigated. Proof of infection was obtained by cultures taken at surgery. All 32 patients showed focally increased uptake on the technetium-99m- (99mTc) methylene diphosphonate (MDP) skeletal scintigraphies. Labeled immunoglobulin correctly identified presence, location, extent and soft-tissue involvement of the suspected inflammatory site. In these patients, focally increasing accumulation was noted over 48 hr. Discrimination between infection and sterile inflammatory lesions was not possible. Two fractures, 6-mo-old, and an aseptic loosening of a total-hip prosthesis were not visualized. Side effects after the immunoglobulin administration were not observed. Radiolabeled immunoglobulin is a new and safe radiopharmaceutical for the investigation of infectious bone and joint disease. The sensitivity of this agent appears at least as high as that of labeled leukocytes. However, labeled immunoglobulin can easily be prepared in every nuclear medicine department.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2324817

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  18 in total

1.  [Diagnosis of septic loosening of hip prosthesis with LeukoScan. SPECT scan with 99mTc-labeled monoclonal antibodies].

Authors:  A Kaisidis; P Megas; D Apostolopoulos; T Spiridonidis; D Koumoundourou; P Zouboulis; E Lambiris; P Vassilakos
Journal:  Orthopade       Date:  2005-05       Impact factor: 1.087

2.  Imaging inflammation with human polyclonal immunoglobulin: not looked for but discovered.

Authors:  F H Corstens; R A Claessens
Journal:  Eur J Nucl Med       Date:  1992

3.  Binding of 99mTc-labelled polyclonal human immunoglobulin to bacteria as a mechanism for scintigraphic detection of infection.

Authors:  W Calame; H I Feitsma; G J Ensing; J W Arndt; R van Furth; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1991

Review 4.  Radiopharmaceuticals: state of the art.

Authors:  A M Verbruggen
Journal:  Eur J Nucl Med       Date:  1990

5.  Technetium-99m human polyclonal immunoglobulin G studies and conventional bone scans to detect active joint inflammation in chronic rheumatoid arthritis.

Authors:  L Berná; G Torres; C Diez; M Estorch; D Martínez-Duncker; I Carrió
Journal:  Eur J Nucl Med       Date:  1992

6.  Imaging experimental intraabdominal abscesses with 99mTc-PEG liposomes and 99mTc-HYNIC IgG.

Authors:  E T Dams; M M Reijnen; W J Oyen; O C Boerman; P Laverman; G Storm; J W van der Meer; F H Corstens; H van Goor
Journal:  Ann Surg       Date:  1999-04       Impact factor: 12.969

7.  Evaluation of four radiopharmaceuticals for imaging inflammation in a rabbit model of arthritis.

Authors:  M Chinol; S Vallabhajosula; S J Goldsmith; G Paganelli; C J Palestro
Journal:  Ann Nucl Med       Date:  1996-08       Impact factor: 2.668

8.  Technetium-99m labelling of human immunoglobulin and preliminary clinical evaluation in tumour patients.

Authors:  A D Varvarigou; S C Archimandritis; A Stripsanelli; A Arka; P Kostamis
Journal:  Eur J Drug Metab Pharmacokinet       Date:  1998 Apr-Jun       Impact factor: 2.441

9.  Immunoscintigraphy with antigranulocyte monoclonal antibodies for the diagnosis of septic loosening of hip prostheses.

Authors:  A Boubaker; A B Delaloye; C H Blanc; M Dutoit; P F Leyvraz; B Delaloye
Journal:  Eur J Nucl Med       Date:  1995-02

10.  Comparison of Tc-99m HIG and Ga-67 citrate in the evaluation of bacterial abscess in a rat model.

Authors:  F Güngör; B Karayalçin; M Gültekin; N Paksoy; U K Sentürk; I Kaputlu; A Yildiz; M Erkiliç
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.