Literature DB >> 2116969

99mTc-human immunoglobulin (HIG)--first results of a new agent for the localization of infection and inflammation.

J R Buscombe1, D Lui, G Ensing, R de Jong, P J Ell.   

Abstract

Technetium (99mTc) labelled, polyclonal human immunoglobulin (HIG) is a new agent that detects focal infection and inflammation. This new agent was compared in 40 patients with the accepted standard, namely 111In-oxine-labelled leucocytes. This comparison resulted in a sensitivity of 94% and a specificity of 96% for 99mTc-HIG when 111In-oxine leucocytes were defined as giving the true result. The new agent was shown to localize both sepsis and active inflammatory bowel disease (IBD). There was 100% concordance in the 16 patients with IBD who were imaged with both 99mTc-HIG and 111In-oxine leucocytes. Discordant results were obtained in one case of suspected osteomyelitis, which was false-positive on the 99mTc-HIG scan, and one case of pyrexia of unknown origin when the 99mTc-HIG was false-negative and the 111In-oxine leucocyte scan demonstrated accumulation of tracer in the caecum at 24 h post-injection. Normal distribution for 99mTc-HIG demonstrated activity in the kidneys and bladder and that 50% of the tracer is cleared through the kidneys during the first 24 h post-injection. There were no major or minor side-effects.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2116969     DOI: 10.1007/bf00998164

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  23 in total

1.  Detection of inflammatory lesions with radiolabelled immunoglobulins.

Authors:  D Blok; M von Ogtrop; J W Arndt; J A Camps; R I Feitsma; W Goedemans; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1990

2.  Technetium-99m autologous phagocyte scanning: a new imaging technique for inflammatory bowel disease.

Authors:  W Pullman; R Hanna; P Sullivan; J A Booth; F Lomas; W F Doe
Journal:  Br Med J (Clin Res Ed)       Date:  1986-07-19

3.  Accumulation of indium-111-labeled granulocytes in malignant tumors.

Authors:  K G Schmidt; J W Rasmussen; I M Wedebye; P B Frederiksen; N T Pedersen
Journal:  J Nucl Med       Date:  1988-04       Impact factor: 10.057

Review 4.  Human immunological response to mouse monoclonal antibodies in the treatment or diagnosis of malignant diseases.

Authors:  M J Van Kroonenburgh; E K Pauwels
Journal:  Nucl Med Commun       Date:  1988-11       Impact factor: 1.690

5.  Localization of indium-111 leukocytes in noninfected neoplasms.

Authors:  L M Lamki; L P Kasi; T P Haynie
Journal:  J Nucl Med       Date:  1988-12       Impact factor: 10.057

6.  Indium-111 chloride imaging in patients with suspected abscesses: concise communication.

Authors:  B A Sayle; S Balachandran; C A Rogers
Journal:  J Nucl Med       Date:  1983-12       Impact factor: 10.057

7.  Cause and significance of cold bone defects on indium-111-labeled leukocyte imaging.

Authors:  F L Datz; D A Thorne
Journal:  J Nucl Med       Date:  1987-05       Impact factor: 10.057

8.  Monoclonal antibodies as agents for selective radiolabeling of human neutrophils.

Authors:  M L Thakur; M D Richard; F W White
Journal:  J Nucl Med       Date:  1988-11       Impact factor: 10.057

9.  Indium-111 leukocyte imaging in appendicitis.

Authors:  D A Navarro; P M Weber; I Y Kang; L V dos Remedios; I A Jasko; J E Sawicki
Journal:  AJR Am J Roentgenol       Date:  1987-04       Impact factor: 3.959

10.  Immunoscintigraphic localization of inflammatory lesions: clinical experience.

Authors:  K Seybold; J T Locher; C Coosemans; R Y Andres; P A Schubiger; P Bläuenstein
Journal:  Eur J Nucl Med       Date:  1988
View more
  21 in total

1.  [Diagnosis of septic loosening of hip prosthesis with LeukoScan. SPECT scan with 99mTc-labeled monoclonal antibodies].

Authors:  A Kaisidis; P Megas; D Apostolopoulos; T Spiridonidis; D Koumoundourou; P Zouboulis; E Lambiris; P Vassilakos
Journal:  Orthopade       Date:  2005-05       Impact factor: 1.087

2.  Imaging inflammation with human polyclonal immunoglobulin: not looked for but discovered.

Authors:  F H Corstens; R A Claessens
Journal:  Eur J Nucl Med       Date:  1992

3.  Binding of 99mTc-labelled polyclonal human immunoglobulin to bacteria as a mechanism for scintigraphic detection of infection.

Authors:  W Calame; H I Feitsma; G J Ensing; J W Arndt; R van Furth; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1991

4.  Technetium-99m human polyclonal immunoglobulin G studies and conventional bone scans to detect active joint inflammation in chronic rheumatoid arthritis.

Authors:  L Berná; G Torres; C Diez; M Estorch; D Martínez-Duncker; I Carrió
Journal:  Eur J Nucl Med       Date:  1992

5.  Inflammatory bowel disease activity assessment using technetium-99m-HMPAO leukocytes.

Authors:  J W Arndt; M I Grootscholten; R A van Hogezand; G Griffioen; C B Lamers; E K Pauwels
Journal:  Dig Dis Sci       Date:  1997-02       Impact factor: 3.199

6.  Immunoscintigraphy with antigranulocyte monoclonal antibodies for the diagnosis of septic loosening of hip prostheses.

Authors:  A Boubaker; A B Delaloye; C H Blanc; M Dutoit; P F Leyvraz; B Delaloye
Journal:  Eur J Nucl Med       Date:  1995-02

7.  Comparison of Tc-99m HIG and Ga-67 citrate in the evaluation of bacterial abscess in a rat model.

Authors:  F Güngör; B Karayalçin; M Gültekin; N Paksoy; U K Sentürk; I Kaputlu; A Yildiz; M Erkiliç
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

8.  Retention of technetium-99m in infectious foci in rats after release from technetium-99m labelled human non-specific polyclonal immunoglobulin G: a dual-label study with hydrazinonicotinamido and iminothiolano immunoglobulin.

Authors:  R A Claessens; E B Koenders; W J Oyen; F H Corstens
Journal:  Eur J Nucl Med       Date:  1996-11

9.  Species and immunoglobulin preparation related effects on the biodistribution of technetium-99m-labelled immunoglobulin G in a baboon model.

Authors:  W K Louw; I C Dormehl; N Hugo; I F Redelinghuys
Journal:  Eur J Nucl Med       Date:  1993-02

10.  Lung scintigraphy with nonspecific human immunoglobulin G ((99m)Tc-HIG) in the evaluation of pulmonary involvement in connective tissue diseases: correlation with pulmonary function tests (PFTs) and high-resolution computed tomography (HRCT).

Authors:  Ch Kostopoulos; J Koutsikos; C Toubanakis; L A Moulopoulos; Ch Mamoulakis; E Gialafos; P P Sfikakis; Ch Zerva; M Mavrikakis; A Leondi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10-06       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.