Literature DB >> 8339482

Extensive osteolysis around an aseptic, stable, uncemented total knee replacement.

D J Berry1, L E Wold, J A Rand.   

Abstract

Extensive osteolysis occurred around an aseptic, well-fixed, stable, uncemented total knee prosthesis. At the time of revision, tibial polyethylene wear and minimal metal-on-metal contact were present. A hypertrophic synovium-like membrane abutted bone in regions of osteolysis. Examination of this membrane revealed polyethylene-wear debris and significant levels of chromium, cobalt, and titanium. Wear debris--polyethylene, metal, or a combination of both--may be responsible for the osteolytic process in this case.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8339482

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  7 in total

1.  A combined XPS-SEM/EDX investigation on explanted UHMW polyethylene acetabular cups: possible role of silicon traces in the wear debris.

Authors:  E De Giglio; A Motta; L Quagliarella; L Sabbatini; G Solarino; P G Zambonin
Journal:  J Mater Sci Mater Med       Date:  2001-01       Impact factor: 3.896

2.  Severe metallosis after unicompartmental knee arthroplasty.

Authors:  Vicente Sanchis-Alfonso
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-10-07       Impact factor: 4.342

3.  Hybrid total knee arthroplasty: 13-year survivorship of AGC total knee systems with average 7 years followup.

Authors:  Philip M Faris; E Michael Keating; Alex Farris; John B Meding; Merrill A Ritter
Journal:  Clin Orthop Relat Res       Date:  2008-03-07       Impact factor: 4.176

4.  Cemented versus cementless fixation in total knee arthroplasty.

Authors:  Fabrizio Matassi; Christian Carulli; Roberto Civinini; Massimo Innocenti
Journal:  Joints       Date:  2014-01-08

5.  Cementless and cemented total knee arthroplasty in patients younger than fifty five years. Which is better?

Authors:  Young-Hoo Kim; Jang-Won Park; Hyung-Mook Lim; Eun-Soo Park
Journal:  Int Orthop       Date:  2014-01-14       Impact factor: 3.075

6.  Vascular endothelial growth factor pathway promotes osseointegration and CD31hiEMCNhi endothelium expansion in a mouse tibial implant model: an animal study.

Authors:  G Ji; R Xu; Y Niu; N Li; L Ivashkiv; M P G Bostrom; M B Greenblatt; X Yang
Journal:  Bone Joint J       Date:  2019-07       Impact factor: 5.082

7.  Can medio-lateral baseplate position and load sharing induce asymptomatic local bone resorption of the proximal tibia? A finite element study.

Authors:  Bernardo Innocenti; Evelyn Truyens; Luc Labey; Pius Wong; Jan Victor; Johan Bellemans
Journal:  J Orthop Surg Res       Date:  2009-07-17       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.