Literature DB >> 8334412

Experimental evaluation of two new sensors for respiratory rate monitoring.

M Vegfors1, H Ugnell, B Hök, P A Oberg, C Lennmarken.   

Abstract

Visual observation was chosen as the reference method for measuring the respiratory rate in ten healthy volunteers. The new fibre-optic and acoustic sensors were simultaneously compared with capnography and transthoracic impedance plethysmography during normoventilation in the respiratory rate range of 6-24 breaths per minute and at a fixed respiratory rate of 13 breaths per minute. In addition a simulation of central apnoea was performed. All the measurements were recorded on an analogue tape recorder and a strip-chart recorder and analysed off line. The analyses of the recordings were performed by a person who was unable to see the monitoring systems. There was no discrepancy in the results of these methods. Each of the methods responded rapidly to an apnoeic event. The new fibre-optic and acoustic sensors correlate well with more traditional methods such as capnography and transthoracic impedance plethysmography for respiratory rate monitoring.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8334412     DOI: 10.1088/0967-3334/14/2/008

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  9 in total

1.  Estimation of respiratory volumes from the photoplethysmographic signal. Part I: Experimental results.

Authors:  A Johansson; P A Oberg
Journal:  Med Biol Eng Comput       Date:  1999-01       Impact factor: 2.602

2.  Evaluation of a new fibre-optical monitor for respiratory rate monitoring.

Authors:  C Larsson; P Staun
Journal:  J Clin Monit Comput       Date:  1999-07       Impact factor: 2.502

Review 3.  Critical review of non-invasive respiratory monitoring in medical care.

Authors:  M Folke; L Cernerud; M Ekström; B Hök
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602

4.  Age and gender do not influence the ability to detect respiration by photoplethysmography.

Authors:  Lena Nilsson; Tomas Goscinski; Anders Johansson; Lars-Göran Lindberg; Sigga Kalman
Journal:  J Clin Monit Comput       Date:  2006-10-11       Impact factor: 2.502

5.  The clinical evaluation of the Respi-check mask: a new oxygen mask incorporating a breathing indicator.

Authors:  A Breakell; C Townsend-Rose
Journal:  Emerg Med J       Date:  2001-09       Impact factor: 2.740

6.  Respiratory monitoring during postoperative analgesia.

Authors:  T Gordh; N Rawal; S Ström; B Hök
Journal:  J Clin Monit       Date:  1995-11

7.  Validation of forehead venous pressure as a measure of respiratory effort for the diagnosis of sleep apnea.

Authors:  Djordje Popovic; Christopher King; Melanie Guerrero; Daniel J Levendowski; Delmer Henninger; Philip R Westbrook
Journal:  J Clin Monit Comput       Date:  2008-12-31       Impact factor: 2.502

8.  The PEP transducer: a new way of measuring respiratory rate in the non-intubated patient.

Authors:  D Dodds; J Purdy; C Moulton
Journal:  J Accid Emerg Med       Date:  1999-01

Review 9.  Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review.

Authors:  Peter H Charlton; Drew A Birrenkott; Timothy Bonnici; Marco A F Pimentel; Alistair E W Johnson; Jordi Alastruey; Lionel Tarassenko; Peter J Watkinson; Richard Beale; David A Clifton
Journal:  IEEE Rev Biomed Eng       Date:  2017-10-24
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.