Abstract

To assess whether aortic valve replacement (AVR) results in changes in the flow velocity distribution in the left ventricular outflow tract (LVOT), 10 patients undergoing AVR for aortic stenosis were studied. By extracting velocity information from color flow maps as digital data, instantaneous cross-sectional velocity profiles were constructed. Velocity profiles obtained 1 to 3 days before AVR were compared with recordings made 3 months later. The LVOT velocity profiles were variably skewed both before and after surgery, and no systematic or uniform changes could be detected after AVR. The highest velocities were most often localized in the region from the center of the outflow tract diameter toward the septum both before and after surgery. At the time of peak flow the ratio of the maximum to the cross-sectional mean velocity was 1.38 +/- 0.13 before and 1.39 +/- 0.08 after AVR (NS), and the ratio of the maximum to the mean velocity time integral was 1.47 +/- 0.10 before and 1.56 +/- 0.10 after (NS). We conclude that AVR in patients with aortic stenosis does not result in a change in LVOT velocity profiles that will influence stroke volume estimates with the Doppler technique.

Entities:  

Mesh:

Year:  1993        PMID: 8333976     DOI: 10.1016/s0894-7317(14)80064-3

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  4 in total

1.  Assessment of prosthetic aortic valve performance by magnetic resonance velocity imaging.

Authors:  R Botnar; E Nagel; M B Scheidegger; E M Pedersen; O Hess; P Boesiger
Journal:  MAGMA       Date:  2000-02       Impact factor: 2.310

2.  Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography.

Authors:  Kian Keong Poh; Robert A Levine; Jorge Solis; Liang Shen; Mary Flaherty; Yue-Jian Kang; J Luis Guerrero; Judy Hung
Journal:  Eur Heart J       Date:  2008-02-09       Impact factor: 29.983

3.  Determination of prestenotic flow volume using an automated method based on colour Doppler imaging for evaluating orifice area by the continuity equation: validation in a pulsatile flow model.

Authors:  K Dennig; H J Nesser; D Hall; H U Haase; A Schömig
Journal:  Heart       Date:  1998-04       Impact factor: 5.994

4.  Measurement errors in serial echocardiographic assessments of aortic valve stenosis severity.

Authors:  Kalie Kebed; Deyu Sun; Karima Addetia; Victor Mor-Avi; Natasha Markuzon; Roberto M Lang
Journal:  Int J Cardiovasc Imaging       Date:  2019-12-21       Impact factor: 2.357