Literature DB >> 8322012

A novel bite force recorder and maximal isometric bite force values for healthy young adults.

A Waltimo1, M Könönen.   

Abstract

Human bite forces have been studied with several types of equipment, and the maximal values reported have varied greatly. In the present study, a new bite force recorder was developed to measure human bite forces. When measuring maximal bite force, the mandible is, laterally and sagittally, almost in the intercuspal position, while the vertical opening of the jaws in the molar region is about 14 mm. Several teeth bite upon the housing. A quartz force transducer serves as a sensory unit. A microprocessor produces a numeric result, shown on a liquid crystal display (LCD). In order to adapt the sensor to be a part of a bite force recorder, we designed a unilateral housing of nonhardened tool steel. In laboratory calibration tests, a series of loads from 112.8 to 1691.5 N was used. The maximal bite forces of healthy undergraduate dental students, 15 men and 15 women, were investigated. The results for both genders remarkably exceeded the values previously reported for unilateral housings. The mean maximal bite force value in the molar region was 847 N for men and 597 N for women. The finding that pain or lack of muscular strength most often limited the clenching suggests that the actual masticatory potential was registered.

Entities:  

Mesh:

Year:  1993        PMID: 8322012     DOI: 10.1111/j.1600-0722.1993.tb01658.x

Source DB:  PubMed          Journal:  Scand J Dent Res        ISSN: 0029-845X


  40 in total

1.  Evaluation of a new optical measuring system for experiments on fractured human mandibles: a biomechanical feasibility study in maxillofacial surgery.

Authors:  T Steiner; S Raith; S Eichhorn; S Doebele; S Trainotti; S Müller; M Eder; L Kovacs; R Burgkart; K-D Wolff; F Hölzle
Journal:  Clin Oral Investig       Date:  2011-12-24       Impact factor: 3.573

2.  Multiscale biomechanical responses of adapted bone-periodontal ligament-tooth fibrous joints.

Authors:  Andrew T Jang; Arno P Merkle; Kevin P Fahey; Stuart A Gansky; Sunita P Ho
Journal:  Bone       Date:  2015-07-04       Impact factor: 4.398

3.  Treatment of mandibular angle fracture with a 2mm, 3 dimensional rectangular grid compression miniplates: A prospective clinical study.

Authors:  Samir Mansuri; Abdul Mujeeb Abdulkhayum; Giath Gazal; Mohammed Abid Zahir Hussain
Journal:  J Int Oral Health       Date:  2013-12-26

4.  [Effects of body-shade resin layer thickness on the color of polyetheretherketone-Crea.lign restorations].

Authors:  Jing-Ting Zhang; Jun Su; Yan-Bo Yuan; Li-Jia He; Wen-Yun Zhang
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2018-10-01

5.  Alternate metal framework designs for the metal ceramic prosthesis to enhance the esthetics.

Authors:  Naina Vilas Vernekar; Prithviraj Kallahalla Jagadish; Srinivasan Diwakar; Ramesh Nadgir; Manjunatha Revankar Krishnarao
Journal:  J Adv Prosthodont       Date:  2011-09-25       Impact factor: 1.904

6.  A study on the fracture strength of collarless metal-ceramic fixed partial dentures.

Authors:  Jong-Wook Yoon; Sung-Hun Kim; Jai-Bong Lee; Jung-Suk Han; Jae-Ho Yang
Journal:  J Adv Prosthodont       Date:  2010-12-31       Impact factor: 1.904

7.  Marginal strength of collarless metal ceramic crown.

Authors:  Sikka Swati; R Chowdhary; P S Patil
Journal:  Int J Dent       Date:  2010-06-01

8.  Bite force and influential factors on bite force measurements: a literature review.

Authors:  Duygu Koc; Arife Dogan; Bulent Bek
Journal:  Eur J Dent       Date:  2010-04

9.  Bite force and pattern measurements for dental pain assessment in the rat.

Authors:  Junad Khan; Rafael Benoliel; Uri Herzberg; Andrew J Mannes; Robert M Caudle; Andrew Young; Eli Eliav
Journal:  Neurosci Lett       Date:  2008-10-07       Impact factor: 3.046

10.  Monolithic and bi-layer CAD/CAM lithium-disilicate versus metal-ceramic fixed dental prostheses: comparison of fracture loads and failure modes after fatigue.

Authors:  Stefan Schultheis; Joerg R Strub; Thomas A Gerds; Petra C Guess
Journal:  Clin Oral Investig       Date:  2012-09-22       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.