| Literature DB >> 8318523 |
P R Gascoyne1, R Pethig, J P Burt, F F Becker.
Abstract
Dielectrophoresis measurements obtained using an image processing technique are reported over the frequency range 1 Hz to 100 kHz for the Friend murine erythroleukemia cell lines DS19 and R1 before and after treatment with hexamethylene bisacetamide and dimethylsulfoxide, agents that induce terminal differentiation in DS19 but not in R1 cells. Data are analyzed according to the single shell dielectric model of the cell. The membrane capacitance was found to fall by 30% and membrane conductivity by a factor of at least 5 when DS19 cells were induced to differentiate. R1 cells showed no such response. While the theoretical model was found to be useful for comparing differences in data for the different cell lines, several significant discrepancies between its predictions and the experimental data were observed, including positive dielectrophoretic collection at frequencies below 20 Hz and a smaller than predicted response to the membrane permeabilizing agents saponin and valinomycin. Factors that may have accounted for these discrepancies include surface charge effecgs, conduction parallel to the plasma membrane surface, and intracellular compartments.Entities:
Mesh:
Substances:
Year: 1993 PMID: 8318523 DOI: 10.1016/0005-2736(93)90032-u
Source DB: PubMed Journal: Biochim Biophys Acta ISSN: 0006-3002