Second harmonic ultrasonic blood perfusion measurement.

B A Schrope1, V L Newhouse.   

Abstract

In vitro and in vivo testing of a recently introduced method of evaluating blood perfusion is presented, where the Doppler shift of the second harmonic component of the backscattered echo is measured. Central to this measurement is the administration of a galactose-based contrast agent (Schering AG, Berlin, Germany, SHU-508 or derivative) which has been shown in vitro to exhibit extraordinary nonlinear backscattering properties. Two types of experiments are described: in vitro studies on excised sheep kidneys and in vivo studies on living rabbits. In the animal model, blood perfusion was manipulated by various mechanisms to obtain some indication of the quantitative ability of the measurement. Comparisons between measurements made at the fundamental component of the backscattered echo and at the second harmonic show that use of the second harmonic measurement results in a much improved ratio of blood echo intensity to tissue echo intensity (signal-to-clutter ratio), allowing detection of blood flowing in smaller vessels and opening up the potential for real-time determination of blood volume fluctuations in tissue.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8310553     DOI: 10.1016/0301-5629(93)90080-8

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  20 in total

1.  Harmonic imaging: echocardiographic enhanced contrast intensity and duration.

Authors:  M R Allen; P A Pellikka; H R Villarraga; K W Klarich; D A Foley; S L Mulvagh; J B Seward
Journal:  Int J Card Imaging       Date:  1999-06

Review 2.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 5.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 6.  [Imaging of molecular structures of breasts with new sonography techniques].

Authors:  M Reisegger; G Schueller; R Gruber; K Pinker; C Riedl; T H Helbich
Journal:  Radiologe       Date:  2010-11       Impact factor: 0.635

7.  Contrast-enhanced ultrasound imaging of prostate cancer.

Authors:  Ethan J Halpern
Journal:  Rev Urol       Date:  2006

8.  Blood perfusion of the contralateral testis evaluated with contrast-enhanced ultrasound in rabbits with unilateral testicular torsion.

Authors:  Lin Chen; Wei-Wei Zhan; Zhou-Jun Shen; Wen-Bin Rui; Chen Lv; Man Chen; Jian-Qiao Zhou; Ping Zhou; Mi Zhou; Ying Zhu
Journal:  Asian J Androl       Date:  2009-01-19       Impact factor: 3.285

9.  [Current developments in vascular ultrasound].

Authors:  A Horng; M Reiser; D-A Clevert
Journal:  Radiologe       Date:  2009-11       Impact factor: 0.635

Review 10.  Contrast echocardiography 1996. A review.

Authors:  H R Villarraga; D A Foley; S L Mulvagh
Journal:  Tex Heart Inst J       Date:  1996
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.