Literature DB >> 8310550

Artifacts in intravascular ultrasound imaging: analyses and implications.

G Finet1, E Maurincomme, A Tabib, R J Crowley, I Magnin, R Roriz, J Beaune, M Amiel.   

Abstract

The ability of an intravascular ultrasound catheter to give cross-sectional images of vessel walls and surrounding tissues, and the behavior of ultrasound in heterogeneous media, are at the origin of degradation of image quality. Qualitative and quantitative analyses of in vivo studies are then operator-dependent and are limited by artifacts. We investigated these limitations by an in vitro study on plexiglass phantoms and segments of fresh arteries. We used a 20 MHz transducer mounted on the tip of a 4.8 F catheter and an interventional ultrasound system. The ultrasound beam is reflected onto the rotating transducer at 600 rotations per minute (RPM), creating 360 degrees real-time images (10 images/second). We then observed, analyzed and interpreted the most specific reasons for image artifacts: geometric distortions, multiple echoes, the point spread function (PSF) of the imaging system, near-field effects, "petal-shaped" effect, and ultrasound speckle. Various practical implications have resulted from this study. Only a thorough knowledge of how to avoid some of the most obvious pitfalls will enable the user to obtain maximum benefits from intravascular ultrasound imaging, and to appreciate its limitations.

Mesh:

Year:  1993        PMID: 8310550     DOI: 10.1016/0301-5629(93)90077-2

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

1.  Mechanism of lumen enlargement with direct stenting versus predilatation stenting: influence of remodelling and plaque characteristics assessed by volumetric intracoronary ultrasound.

Authors:  G Finet; N J Weissman; G S Mintz; L F Satler; K M Kent; J R Laird; G A Adelmann; A E Ajani; M T Castagna; G Rioufol; A D Pichard
Journal:  Heart       Date:  2003-01       Impact factor: 5.994

2.  Assessing atherosclerotic plaque morphology: comparison of optical coherence tomography and high frequency intravascular ultrasound.

Authors:  M E Brezinski; G J Tearney; N J Weissman; S A Boppart; B E Bouma; M R Hee; A E Weyman; E A Swanson; J F Southern; J G Fujimoto
Journal:  Heart       Date:  1997-05       Impact factor: 5.994

3.  Parameters that influence accuracy and precision of quantitative coronary arteriography.

Authors:  G Finet; J Liénard
Journal:  Int J Card Imaging       Date:  1996-12

Review 4.  Intravascular ultrasound: principles and cerebrovascular applications.

Authors:  H Zacharatos; A E Hassan; A I Qureshi
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-04       Impact factor: 3.825

Review 5.  The role of noninvasive and invasive diagnostic imaging techniques for detection of extra-cranial venous system anomalies and developmental variants.

Authors:  Kresimir Dolic; Adnan H Siddiqui; Yuval Karmon; Karen Marr; Robert Zivadinov
Journal:  BMC Med       Date:  2013-06-27       Impact factor: 8.775

  5 in total