Mechanism of lumen enlargement with direct stenting versus predilatation stenting: influence of remodelling and plaque characteristics assessed by volumetric intracoronary ultrasound.

G Finet1, N J Weissman, G S Mintz, L F Satler, K M Kent, J R Laird, G A Adelmann, A E Ajani, M T Castagna, G Rioufol, A D Pichard.   

Abstract

OBJECTIVE: To compare the effects of arterial remodelling and plaque characteristics on the mechanisms of direct stenting and predilatation stenting. Direct stenting has become routine in some laboratories and differs technically from predilatation stenting.
METHODS: Pre- and post-interventional volumetric intravascular ultrasound (IVUS) was undertaken in 30 patients with direct stenting and in 30 with predilatation stenting of non-calcified native coronary lesions, using the same stent design and stent length. Lumen, vessel (external elastic membrane (EEM)), and plaque (plaque + media) volumes were calculated. Remodelling was determined by comparing the EEM area at the centre of the lesion with the EEM areas at proximal and distal reference sites. Plaque eccentricity was defined as the thinnest plaque diameter to the thickest plaque diameter ratio. Plaque composition was characterised as soft, mixed, or dense.
RESULTS: All volumetric IVUS changes were similar in the two groups. Pre-intervention remodelling remained uninfluenced after direct stenting, but was neutralised after predilatation stenting. Eccentric lesions responded to intervention by a greater luminal gain owing to greater vessel expansion in direct stenting. Plaque composition influenced luminal gain in direct stenting, the gain being greatest in the softest plaques; in predilatation stenting, luminal gain was equivalent but vessel expansion was greater for "dense" plaque and plaque reduction greater for "soft" plaque.
CONCLUSIONS: In non-calcified lesions, the mechanisms of lumen enlargement after direct or predilatation stenting are significantly influenced by atherosclerotic remodelling, plaque eccentricity, and plaque composition.

Entities:  

Mesh:

Year:  2003        PMID: 12482801      PMCID: PMC1767502          DOI: 10.1136/heart.89.1.84

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  23 in total

1.  Coronary stenting without predilatation (SWOP): applicable technique in everyday practice.

Authors:  I Herz; A Assali; A Solodky; N S Simcha Brandes; N Buto; I Teplizky; H Menkes; E Rechavia; D Hasdai; T Ben-Gal; Y Adler
Journal:  Catheter Cardiovasc Interv       Date:  2000-04       Impact factor: 2.692

2.  Radial force of coronary stents: a comparative analysis.

Authors:  R Rieu; P Barragan; C Masson; J Fuseri; V Garitey; M Silvestri; P Roquebert; J Sainsous
Journal:  Catheter Cardiovasc Interv       Date:  1999-03       Impact factor: 2.692

3.  Artifacts in intravascular ultrasound imaging during coronary artery stent implantation.

Authors:  G Finet; C Cachard; P Delachartre; E Maurincomme; J Beaune
Journal:  Ultrasound Med Biol       Date:  1998-07       Impact factor: 2.998

4.  Direct stent implantation without predilatation using the MultiLink stent.

Authors:  D Pentousis; Y Guérin; F Funck; H Zheng; M Toussaint; T Corcos; X Favereau
Journal:  Am J Cardiol       Date:  1998-12-15       Impact factor: 2.778

Review 5.  Clinical application and image interpretation in intracoronary ultrasound. Study Group on Intracoronary Imaging of the Working Group of Coronary Circulation and of the Subgroup on Intravascular Ultrasound of the Working Group of Echocardiography of the European Society of Cardiology.

Authors:  C Di Mario; G Görge; R Peters; P Kearney; F Pinto; D Hausmann; C von Birgelen; A Colombo; H Mudra; J Roelandt; R Erbel
Journal:  Eur Heart J       Date:  1998-02       Impact factor: 29.983

6.  How should we define inadequate coronary arterial remodeling?

Authors:  T Nishioka; H Berglund; H Luo; T Nagai; R J Siegel
Journal:  Circulation       Date:  1998-04-14       Impact factor: 29.690

7.  Preintervention lesion remodelling affects operative mechanisms of balloon optimised directional coronary atherectomy procedures: a volumetric study with three dimensional intravascular ultrasound.

Authors:  C von Birgelen; G S Mintz; E A de Vrey; P W Serruys; T Kimura; M Nobuyoshi; J J Popma; M B Leon; R Erbel; P J de Feyter
Journal:  Heart       Date:  2000-02       Impact factor: 5.994

8.  Dynamic expansion of the coronary arteries: implications for intravascular ultrasound measurements.

Authors:  N J Weissman; I F Palacios; A E Weyman
Journal:  Am Heart J       Date:  1995-07       Impact factor: 4.749

9.  In vitro analysis of coronary atheromatous lesions by intravascular ultrasound; reproducibility and histological correlation of lesion morphology.

Authors:  N D Palmer; D Northridge; A Lessells; W N McDicken; K A Fox
Journal:  Eur Heart J       Date:  1999-12       Impact factor: 29.983

10.  Influence of coronary atherosclerotic remodeling on the mechanism of balloon angioplasty.

Authors:  S B Timmis; W J Burns; J B Hermiller; M A Parker; S N Meyers; C J Davidson
Journal:  Am Heart J       Date:  1997-12       Impact factor: 4.749

View more
  3 in total

1.  Mechanical properties of normal and diseased cerebrovascular system.

Authors:  Ali P Ebrahimi
Journal:  J Vasc Interv Neurol       Date:  2009-04

2.  Three-dimensional visualization of scoring mechanism of 'AngioSculpt' balloon for calcified coronary lesions using optical coherence tomography.

Authors:  Takashi Kanai; Takafumi Hiro; Tadateru Takayama; Daisuke Fukamachi; Yasuo Watanabe; Makoto Ichikawa; Taro Kawano; Atsushi Hirayama
Journal:  J Cardiol Cases       Date:  2011-11-27

3.  Comparative analysis of lumen enlargement mechanisms achieved with the bifurcation dedicated BiOSS) stent versus classical coronary stent implantations by means of provisional side branch stenting strategy: an intravascular ultrasound study.

Authors:  Robert J Gil; Jacek Bil; Aleksandra Michałek; Dobrin Vassiliev; Ricardo A Costa
Journal:  Int J Cardiovasc Imaging       Date:  2013-07-19       Impact factor: 2.357

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.