Literature DB >> 8310153

A verification procedure to improve patient set-up accuracy using portal images.

A Bel1, M van Herk, H Bartelink, J V Lebesque.   

Abstract

The purpose of this study was to establish which level of geometrical accuracy can be obtained during radiotherapy, using portal image analysis, with a minimum number of patient set-up measurements and corrections. A set-up verification and correction procedure using decision rules for improving the set-up of a patient during radiotherapy was investigated by means of a computer simulation. In this simulation study, set-up deviations were assumed to be the sum of random and systematic deviations and varying ratios of random and systematic deviations were studied. The distribution of random deviations (SD equal to sigma) was assumed to be equal for all patients of a specific treatment site. Set-up deviations are measured during the first N consecutive fractions after the start of the treatment or after a patient set-up correction. A set-up is corrected when the deviation averaged over these measurements is larger than an N-dependent action level. This action level is specified by alpha/square root of N, in which alpha is a variable initial action level parameter. After the start of the treatment or after each correction, Nmax measurements are made to decide on a possible (further) correction. By varying alpha and Nmax, the relation between the overall accuracy and the workload has been analyzed. It was possible to obtain a resulting overall accuracy level which is almost independent of the initial distribution of systematic deviations.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1993        PMID: 8310153     DOI: 10.1016/0167-8140(93)90255-7

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  25 in total

1.  Investigating the Electronic Portal Imaging Device for Small Radiation Field Measurements.

Authors:  Arpita Agarwal; Nikhil Rastogi; K J Maria Das; S A Yoganathan; D Udayakumar; Shaleen Kumar
Journal:  J Med Phys       Date:  2017 Apr-Jun

2.  Registration of clinical volumes to beams-eye-view images for real-time tracking.

Authors:  Jonathan H Bryant; Joerg Rottmann; John H Lewis; Pankaj Mishra; Paul J Keall; Ross I Berbeco
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

3.  Pretreatment verification of dose calculation and delivery by means of measurements with PLEXITOM™ phantom.

Authors:  Paweł Wołowiec; Paweł Kukołowicz; Krzysztof Lis
Journal:  Rep Pract Oncol Radiother       Date:  2013-02-04

4.  Adaptive off-line protocol for prostate external radiotherapy with cone beam computer tomography.

Authors:  M Piziorska; P Kukołowicz; A Zawadzka; M Pilichowska; P Pęczkowski
Journal:  Strahlenther Onkol       Date:  2012-10-10       Impact factor: 3.621

Review 5.  Adaptive radiation therapy for prostate cancer.

Authors:  Michel Ghilezan; Di Yan; Alvaro Martinez
Journal:  Semin Radiat Oncol       Date:  2010-04       Impact factor: 5.934

6.  Dependence of the safe rectum dose on the CTV-PTV margin size and treatment technique.

Authors:  Pawel Kukołowicz; Helena Kukołowicz; Izabela Tyburska
Journal:  Rep Pract Oncol Radiother       Date:  2015-01-07

7.  Relocatable fixation systems in intracranial stereotactic radiotherapy. Accuracy of serial CT scans and patient acceptance in a randomized design.

Authors:  A Theelen; J Martens; G Bosmans; R Houben; J J Jager; I Rutten; P Lambin; A W Minken; B G Baumert
Journal:  Strahlenther Onkol       Date:  2011-12-24       Impact factor: 3.621

8.  Assessment and quantification of patient set-up errors in nasopharyngeal cancer patients and their biological and dosimetric impact in terms of generalized equivalent uniform dose (gEUD), tumour control probability (TCP) and normal tissue complication probability (NTCP).

Authors:  A Boughalia; S Marcie; M Fellah; S Chami; F Mekki
Journal:  Br J Radiol       Date:  2015-04-17       Impact factor: 3.039

9.  Volume changes in soft tissue sarcomas during preoperative radiotherapy of extremities evaluated using cone-beam CT.

Authors:  Anja Betgen; Rick L M Haas; Jan-Jakob Sonke
Journal:  J Radiat Oncol       Date:  2013-01-04

10.  Evaluation of combining bony anatomy and soft tissue position correction strategies for IMRT prostate cancer patients.

Authors:  Marta Adamczyk; Tomasz Piotrowski; Ewa Adamiak
Journal:  Rep Pract Oncol Radiother       Date:  2012-02-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.