Literature DB >> 8295010

A quantitative phantom analysis of artifacts due to hepatic activity in technetium-99m myocardial perfusion SPECT studies.

G Germano1, T Chua, H Kiat, J S Areeda, D S Berman.   

Abstract

UNLABELLED: We have observed that filtered backprojection may cause artifactual decreased myocardial wall uptake in the reconstructed images if the hepatic-to-cardiac activity ratio (HCR) in 99mTc clinical myocardial SPECT studies is sufficiently high (> 1).
METHODS: To quantitatively relate hepatic uptake to this phenomenon, a commercial chest and heart phantom was modified with the addition of a customized liver insert, which was filled with various concentrations of 99mTc to simulate HCRs of 0:1, 1:1 and 2:1. The phantom was imaged with a high-sensitivity, three-detector camera, low-energy, high-resolution (LEHR) collimation and 180 degrees noncircular orbits.
RESULTS: Quantitative circumferential profile analysis of the reoriented SPECT images demonstrated artifactual inferior/inferoseptal maximal activity decreases of 17.8% and 46.2% for the 1:1 and 2:1 HCRs, compared to the 0:1 HCR. Hepatic scatter probably partly mitigates the decrease. Smoothing the projection data before reconstruction worsened the artifacts' severity. Using Butterworth filters of order 5 and cutoff frequencies of 0.1, 0.2 and 0.215 Nyquist (clinical standard) resulted in artifactual inferior wall activity decreases of 5%, 8% and 16%, compared to using the same filter with a cutoff of 0.3 for an HCR of 2:1.
CONCLUSION: These data indicate that if count statistics are good and liver uptake is high, higher frequency cutoffs in pre-reconstruction filters may improve specificity in 99mTc-labeled myocardial perfusion SPECT studies.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8295010

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  36 in total

1.  Use of rotating (cine) planar projection images in the interpretation of a tomographic myocardial perfusion study.

Authors:  R C Hendel; R J Gibbons; T M Bateman
Journal:  J Nucl Cardiol       Date:  1999 Mar-Apr       Impact factor: 5.952

2.  Effects of motion, attenuation, and scatter corrections on gated cardiac SPECT reconstruction.

Authors:  Xiaofeng Niu; Yongyi Yang; Mingwu Jin; Miles N Wernick; Michael A King
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

3.  Diagnostic value of myocardial SPECT to detect in-stent restenosis after drug-eluting stent implantation.

Authors:  Hyo Eun Park; Bon-Kwon Koo; Kyung-Woo Park; Jin Chul Paeng; Hae-Young Lee; Hyun-Jae Kang; Hyo-Soo Kim
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-07       Impact factor: 2.357

Review 4.  Value of coronary CTA in patients with known or suspected CAD and non-diagnostic initial myocardial perfusion testing: current evidence and clinical considerations.

Authors:  Aiden Abidov; Gilbert L Raff
Journal:  J Nucl Cardiol       Date:  2010-12       Impact factor: 5.952

5.  Journey to find the ideal PET flow tracer for clinical use: are we there yet?

Authors:  David K Glover; Robert J Gropler
Journal:  J Nucl Cardiol       Date:  2007 Nov-Dec       Impact factor: 5.952

6.  Organ biodistribution and myocardial uptake, washout, and redistribution kinetics of Tc-99m N-DBODC5 when injected during vasodilator stress in canine models of coronary stenoses.

Authors:  Kengo Hatada; Mirta Ruiz; Laurent M Riou; Ronaldo L Lima; Allen R Goode; Denny D Watson; George A Beller; David K Glover
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

Review 7.  Quantitative myocardial perfusion SPECT.

Authors:  B M Tsui; E C Frey; K J LaCroix; D S Lalush; W H McCartney; M A King; G T Gullberg
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

8.  A Monte Carlo investigation of artifacts caused by liver uptake in single-photon emission computed tomography perfusion imaging with technetium 99m-labeled agents.

Authors:  M A King; W Xia; D J deVries; T S Pan; B J Villegas; S Dahlberg; B M Tsui; M H Ljungberg; H T Morgan
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

9.  Phantom evaluation of simultaneous thallium-201/technetium-99m aquisition in single-photon emission tomography.

Authors:  Z Cao; C C Chen; C Maunoury; L E Holder; T C Abraham; A Tehan
Journal:  Eur J Nucl Med       Date:  1996-11

10.  Evaluation of an attenuation correction method for thallium-201 myocardial perfusion tomographic imaging of patients with low likelihood of coronary artery disease.

Authors:  P Chouraqui; S Livschitz; T Sharir; N Wainer; M Wilk; I Moalem; J Baron
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.