Literature DB >> 8293260

A frameless method for stereotactic radiotherapy.

D Jones1, D A Christopherson, J T Washington, M D Hafermann, J W Rieke, J J Travaglini, S S Vermeulen.   

Abstract

A frameless method for stereotactic multiple arc radiotherapy (SMART) is described. Three short gold wires are implanted in the scalp approximately 100 mm apart. These are localized in a computed tomographic or angiographic study along with the target. Subsequently the gold markers are localized on beam films and the target position calculated using a computer program ISOLOC. This program provides the couch movements required to move the target to the isocentre and a micropositioner attached to the couch is used to make the adjustment. Beam films are repeated until the movements required are less than 1 mm in any direction. It is shown that the simple procedures of implanting the markers subcutaneously do not provide a stable reference system in about 25% of patients and the markers are now screwed into the cranium. The precision of the method is evaluated by phantom studies and measurements taken during several hundred treatments.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8293260     DOI: 10.1259/0007-1285-66-792-1142

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  4 in total

1.  Analysis of fiducial markers used for on-line verification in the external-beam radiotherapy of patients with cranial tumours.

Authors:  R Ma Cañón; I Azinovic; M Lobato; J Navarro; J Rebollo
Journal:  Clin Transl Oncol       Date:  2007-08       Impact factor: 3.405

2.  Frameless linac-based stereotactic radiosurgery (SRS) for brain metastases: analysis of patient repositioning using a mask fixation system and clinical outcomes.

Authors:  Giuseppe Minniti; Claudia Scaringi; Enrico Clarke; Maurizio Valeriani; Mattia Osti; Riccardo Maurizi Enrici
Journal:  Radiat Oncol       Date:  2011-11-16       Impact factor: 3.481

3.  Analysis of inter- and intrafraction accuracy of a commercial thermoplastic mask system used for image-guided particle radiation therapy.

Authors:  Dante Amelio; Marcus Winter; Daniel Habermehl; Oliver Jäkel; Jurgen Debus; Stephanie E Combs
Journal:  J Radiat Res       Date:  2013-07       Impact factor: 2.724

4.  Fractionated stereotactic radiotherapy for skull base tumors: analysis of treatment accuracy using a stereotactic mask fixation system.

Authors:  Giuseppe Minniti; Maurizio Valeriani; Enrico Clarke; Marco D'Arienzo; Michelangelo Ciotti; Roberto Montagnoli; Francesca Saporetti; Riccardo Maurizi Enrici
Journal:  Radiat Oncol       Date:  2010-01-13       Impact factor: 3.481

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.