Literature DB >> 8269564

Capnometry and the paediatric laryngeal mask airway.

I A Spahr-Schopfer1, B Bissonnette, E J Hartley.   

Abstract

The laryngeal mask airway (LMA), an alternative to tracheal intubation in certain situations, has gained popularity in recent years. Initially designed for use in adults it has now become available in suitable sizes for paediatric anaesthesia. The objectives of this study were to identify the preferred site of sampling the end-tidal carbon dioxide (PETCO2) with the LMA and to determine the accuracy of this recording when compared with arterial CO2 (PaCO2). We studied 30 healthy children, age one to five years and weighing between 10 and 25 kg undergoing minor surgery requiring mask anaesthesia. In each case, after induction of anaesthesia, the LMA was inserted under direct vision to eliminate the possibility of epiglottic airway obstruction. The fresh gas flow was provided by a Jackson Rees modification of an Ayre's T-piece and was determined according to the following formula: 3 x (1000 + (100 x body weight)) LPM. Blood pressure, ECG, O2 saturation, temperature and end-tidal gas concentrations were recorded. The measures of peak PETCO2 were taken at pre-determined distances from the elbow connector down the LMA shaft. During the sampling sequence an arterial blood sample was taken for gas analysis. The PaCO2 was 63.5 +/- 9.3 mmHg (mean +/- SD). At any given sampling site, mean PETCO2 values were less than PaCO2 (P < 0.05). However, in eight patients PETCO2 values measured at the distal site were higher than the PaCO2 (negative P(a-ET)CO2 gradients).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8269564     DOI: 10.1007/BF03009474

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  19 in total

1.  Accuracy of end-tidal PCO2 measurements using a sidestream capnometer in infants and children ventilated with the Sechrist infant ventilator.

Authors:  S C Hillier; J M Badgwell; M E McLeod; R E Creighton; J Lerman
Journal:  Can J Anaesth       Date:  1990-04       Impact factor: 5.063

2.  Effects of halothane, isoflurane and enflurane on ventilation in children.

Authors:  W S Wren; P Allen; A Synnott; D O'Keeffe; P O'Griofa
Journal:  Br J Anaesth       Date:  1987-04       Impact factor: 9.166

3.  Carbon dioxide elimination during spontaneous ventilation with a modified Mapleson D system: studies in a lung model.

Authors:  D K Rose; R J Byrick; A B Froese
Journal:  Can Anaesth Soc J       Date:  1978-09

4.  Is distal sampling of end-tidal CO2 necessary in small subjects?

Authors:  G F Rich; M P Sullivan; J M Adams
Journal:  Anesthesiology       Date:  1990-08       Impact factor: 7.892

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Error in sampling of exhaled gases.

Authors:  R F Kaplan; D A Paulus
Journal:  Anesth Analg       Date:  1983-10       Impact factor: 5.108

7.  Factors influencing capnography in the Bain circuit.

Authors:  N Gravenstein; S Lampotang; J E Beneken
Journal:  J Clin Monit       Date:  1985-01

8.  Technical and clinical aspects of capnography in neonates.

Authors:  H Kirpalani; S Kechagias; J Lerman
Journal:  J Med Eng Technol       Date:  1991 Jul-Oct

9.  End-tidal PCO2 monitoring in infants and children ventilated with either a partial rebreathing or a non-rebreathing circuit.

Authors:  J M Badgwell; J E Heavner; W S May; J F Goldthorn; J Lerman
Journal:  Anesthesiology       Date:  1987-03       Impact factor: 7.892

10.  Prediction of the physiological dead space/tidal volume ratio during anaesthesia/IPPV from simple pre-operative tests.

Authors:  R Fletcher; B Jonson
Journal:  Acta Anaesthesiol Scand       Date:  1981-02       Impact factor: 2.105

View more
  1 in total

Review 1.  A review of pediatric capnography.

Authors:  Naveen Eipe; Dermot R Doherty
Journal:  J Clin Monit Comput       Date:  2010-07-16       Impact factor: 2.502

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.