Validation of volumetric flow measurements by means of a Doppler-tipped coronary angioplasty guide wire.

A J Labovitz1, D M Anthonis, T L Cravens, M J Kern.   

Abstract

We used an in vitro model to validate volumetric flow measurements obtained with an 0.018-inch angioplasty guidewire with a 12 MHz transducer mounted on its tip. By using a modified two-head roller pump device, flow was adjusted incrementally from a minimum of 90 ml/min to a maximum of 550 ml/min. Flow was measured with the Doppler guide wire in tubing ranging from 1.9 mm to 6.0 mm internal diameter, as the product of the spectral Doppler velocity integral and the cross-sectional area of the tubing, over a 1-minute period. It was an excellent correlation between the Doppler calculated flow rates and actual flow, regardless of tubing diameter (r = 0.99). These results suggest that the Doppler spectral output of this device might be accurately applied to estimates of volumetric flow in human coronary arteries.

Entities:  

Mesh:

Year:  1993        PMID: 8249803     DOI: 10.1016/0002-8703(93)90545-k

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  8 in total

1.  Hemodynamic evaluation of saphenous vein coronary artery bypass grafts: relative merits of Doppler flow velocity and SPECT perfusion imaging.

Authors:  Liesbeth P Salm; Jeroen J Bax; J Wouter Jukema; Susan E Langerak; Hubert W Vliegen; Paul Steendijk; Hildo J Lamb; Albert de Roos; Ernst E van der Wall
Journal:  J Nucl Cardiol       Date:  2005 Sep-Oct       Impact factor: 5.952

2.  Assessment of the arterial input function for estimation of coronary flow reserve by single photon emission computed tomography: comparison of two different approaches.

Authors:  Giovanni Storto; Andrea Soricelli; Teresa Pellegrino; Mario Petretta; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

3.  Clinical methods to determine coronary flow and myocardial perfusion.

Authors:  M J Wolters-Geldof; V M Cats; A V Bruschke
Journal:  Int J Card Imaging       Date:  1997-04

Review 4.  New concepts for interpretation of intracoronary velocity and pressure tracings.

Authors:  C Di Mario; R Gil; M Sunamura; P W Serruys
Journal:  Br Heart J       Date:  1995-11

Review 5.  Assessment of coronary flow reserve using single photon emission computed tomography with technetium 99m-labeled tracers.

Authors:  Mario Petretta; Andrea Soricelli; Giovanni Storto; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2008 May-Jun       Impact factor: 5.952

6.  In vitro validation of endovascular Doppler-derived flow rates in models of the cerebral circulation.

Authors:  P M McGah; J D Nerva; R P Morton; M C Barbour; M R Levitt; P D Mourad; L J Kim; A Aliseda
Journal:  Physiol Meas       Date:  2015-10-09       Impact factor: 2.833

7.  Lack of association between Chlamydia Pneumoniae serology and endothelial dysfunction of coronary arteries.

Authors:  Markus Ferrari; Gerald S Werner; Barbara M Richartz; Albrecht Oehme; Eberhard Straube; Hans R Figulla
Journal:  Cardiovasc Ultrasound       Date:  2005-04-27       Impact factor: 2.062

8.  Turbulent flow as a cause for underestimating coronary flow reserve measured by Doppler guide wire.

Authors:  Markus Ferrari; Gerald S Werner; Philipp Bahrmann; Barbara M Richartz; Hans R Figulla
Journal:  Cardiovasc Ultrasound       Date:  2006-03-22       Impact factor: 2.062