Literature DB >> 8245055

Severe osteolysis of the pelvic in association with acetabular replacement without cement.

W J Maloney1, P Peters, C A Engh, H Chandler.   

Abstract

We reviewed the cases of fourteen patients (fifteen lesions) who had osteolysis following the replacement of the acetabulum without cement. Nine women and five men, seventeen to sixty-seven years old, were involved in the study. One woman had bilateral pelvic osteolysis. Eight of the fifteen index acetabular reconstructions were done with a titanium-alloy implant and seven, with a chromium-cobalt-alloy implant. Eleven of the fifteen acetabular components had holes in the metal shell that may have acted as a conduit through which wear debris could gain access to the implant-bone interface, but only two of the acetabular components had been fixed with screws. In these two acetabular components, all available screw holes were not filled. The polyethylene liner was eight millimeters thick or less in twelve of the fifteen acetabular components; all of the liners were ten millimeters thick or less. The diameter of the head of eleven of the fifteen femoral components was thirty-two millimeters. Fourteen of the fifteen femoral components were placed without cement, and all but one was radiographically stable. The duration from the index operation to the appearance of pelvic osteolysis ranged from fifty-three to eighty-four months (mean, sixty-five months). At the time of the diagnosis, the patients were functioning well clinically, and all but three had a Harris hip score of 90 points or better, despite extensive destruction of bone in some instances. Since these patients were functioning well, the pelvic osteolysis was diagnosed radiographically at a regular follow-up examination. Only one patient had evidence of migration of the acetabular component on serial radiographs.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8245055     DOI: 10.2106/00004623-199311000-00007

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  8 in total

Review 1.  Treatment algorithm of acetabular periprosthetic fractures.

Authors:  Paul Simon; Philipp von Roth; Carsten Perka
Journal:  Int Orthop       Date:  2015-08-30       Impact factor: 3.075

2.  Effect of design on the initial stability of press-fit cups in the presence of acetabular rim defects: experimental evaluation of the effect of adding circumferential fins.

Authors:  Wolfgang O Huber; Philip C Noble
Journal:  Int Orthop       Date:  2013-11-22       Impact factor: 3.075

3.  Complications of total hip arthroplasty: periprosthetic fractures of the acetabulum.

Authors:  Amol Chitre; Henry Wynn Jones; Nikhil Shah; Anthony Clayson
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

4.  What is the role of magnetic resonance imaging in the evaluation of total hip arthroplasty?

Authors:  Hollis G Potter; Li F Foo; Bryan J Nestor
Journal:  HSS J       Date:  2005-09

5.  [Impacted acetabular cups].

Authors:  A Dambreville; P Lautridou
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-10

6.  Two-stage management of a spontaneous fracture of the greater trochanter through osteolytic lesions induced by polyethylene wear of a total hip arthroplasty. A case report.

Authors:  Dario Regis; Andrea Sandri; Elena Samaila; Bruno Magnan
Journal:  Acta Biomed       Date:  2019-01-10

7.  Results of the cementless Mallory-Head primary total hip arthroplasty: a 5 to 7 year review.

Authors:  B D Mulliken; R B Bourne; C H Rorabeck; N Nayak
Journal:  Iowa Orthop J       Date:  1996

8.  Pre-surgical radiologic identification of peri-prosthetic osteolytic lesions around TKRs: a pre-clinical investigation of diagnostic accuracy.

Authors:  Timothy P Kurmis; Andrew P Kurmis; David G Campbell; John P Slavotinek
Journal:  J Orthop Surg Res       Date:  2008-10-03       Impact factor: 2.359

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.