Validity and reliability of the Cosmed K2 instrument.

A Lucía1, S J Fleck, R W Gotshall, J T Kearney.   

Abstract

The purpose of this study was to measure the validity and reliability of a portable telemetry system (Cosmed K2) for measurement of oxygen consumption (VO2) during a laboratory exercise test at submaximum and maximum intensities. Twenty subjects performed three testing sessions on a treadmill on three consecutive days. Each testing session consisted of a submaximal and a maximal exercise test. On one day, VO2 was determined with the conventional Douglas bag method, and on the other two days, VO2 was determined using the Cosmed K2 system. Utilization of the Douglas bag method or the Cosmed K2 was randomly assigned. The results indicated that the Cosmed K2 instrument is reliable and valid (p > 0.05) for measurement of VO2 (l.min-1) during laboratory exercise testing at submaximum and maximum intensities. The assumption made by the K2 apparatus of a constant respiratory gas exchange ratio (R) of 1.00 did not have a significant influence on VO2 measurements.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8244604     DOI: 10.1055/s-2007-1021196

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  12 in total

1.  Dependence of the maximal lactate steady state on the motor pattern of exercise.

Authors:  R Beneke; R M Leithäuser; M Hütler
Journal:  Br J Sports Med       Date:  2001-06       Impact factor: 13.800

Review 2.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

3.  Accuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems.

Authors:  Scott E Crouter; Amanda Antczak; Jonathan R Hudak; Diane M DellaValle; Jere D Haas
Journal:  Eur J Appl Physiol       Date:  2006-08-03       Impact factor: 3.078

Review 4.  Automated metabolic gas analysis systems: a review.

Authors:  D J Macfarlane
Journal:  Sports Med       Date:  2001       Impact factor: 11.136

5.  Comparison of gas exchange data using the Aquatrainer system and the facemask with Cosmed K4b2 during exercise in healthy subjects.

Authors:  Mathieu Gayda; Laurent Bosquet; Martin Juneau; Thibaut Guiraud; Jean Lambert; Anil Nigam
Journal:  Eur J Appl Physiol       Date:  2010-01-05       Impact factor: 3.078

Review 6.  The energetics of cycling on Earth, Moon and Mars.

Authors:  Stefano Lazzer; Luca Plaino; Guglielmo Antonutto
Journal:  Eur J Appl Physiol       Date:  2010-03-27       Impact factor: 3.078

7.  Increase in energy cost of running at the end of a triathlon.

Authors:  C Y Guezennec; J M Vallier; A X Bigard; A Durey
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996

8.  The upper limit of aerobic power in humans.

Authors:  Martin Burtscher; Werner Nachbauer; Randall Wilber
Journal:  Eur J Appl Physiol       Date:  2011-03-04       Impact factor: 3.078

9.  Physical activity energy expenditure measured using a portable telemetric device in comparison with a mass spectrometer.

Authors:  C Maiolo; G Melchiorri; L Iacopino; S Masala; A De Lorenzo
Journal:  Br J Sports Med       Date:  2003       Impact factor: 13.800

10.  Responses of people with coronary artery disease to common lawn-care tasks.

Authors:  L M Sheldahl; N A Wilke; R D Hanna; S M Dougherty; F E Tristani
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1996
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.