Literature DB >> 8233372

Assessment of the reliability of calculations of the coefficient of variation for normal and polymegethous human corneal endothelium.

M J Doughty1, D Fonn, K Trang Nguyen.   

Abstract

In endothelial morphometry, uncertainty exists concerning how many cells should be measured. A study was undertaken to calculate mean cell area and coefficient of variation (COV) of cell areas using different numbers of cells from photo-slitlamp pictures and published micrographs. Groups of 65, 95, or 165 tesselated cells were measured and area and COV values calculated in progressive sets of 5 cells; each pair of values was compared to that obtained using all cells in each group. The results show that, for both normal (homomegethous) and irregular (polymegethous) endothelia, even cell counts as low as 50 cells can usually provide average cell area values that are within 1 to 2% of the values estimated from larger groups of cells. A similar reliability was observed for estimates of COV for normal endothelia. However, for polymegethous endothelia, even with 100 cells analyzed, the estimates of COV generally only approached a +/- 4% reliability. This uncertainty in COV estimates should be considered in both comparative studies and in regression analyses of COV changes over time or other variables.

Entities:  

Mesh:

Year:  1993        PMID: 8233372     DOI: 10.1097/00006324-199309000-00013

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  6 in total

1.  Automated tri-image analysis of stored corneal endothelium.

Authors:  P Gain; G Thuret; L Kodjikian; Y Gavet; P H Turc; C Theillere; S Acquart; J C Le Petit; J Maugery; L Campos
Journal:  Br J Ophthalmol       Date:  2002-07       Impact factor: 4.638

2.  Corneal endothelial cell analysis using two non-contact specular microscopes in healthy subjects.

Authors:  Manuel Garza-Leon
Journal:  Int Ophthalmol       Date:  2015-10-05       Impact factor: 2.031

3.  Assessment of the reliability of endothelial cell-density estimates in the presence of pseudoguttata.

Authors:  Michael J Doughty; Sven Jonuscheit; Norman F Button
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-09-13       Impact factor: 3.117

4.  Comparison of central corneal thickness and endothelial cell measurements by Scheimpflug camera system and two noncontact specular microscopes.

Authors:  Irmak Karaca; Suzan Guven Yilmaz; Melis Palamar; Halil Ates
Journal:  Int Ophthalmol       Date:  2017-07-03       Impact factor: 2.031

5.  Endothelial morphometric measures to predict endothelial graft failure after penetrating keratoplasty.

Authors:  Beth Ann Benetz; Jonathan H Lass; Robin L Gal; Alan Sugar; Harry Menegay; Mariya Dontchev; Craig Kollman; Roy W Beck; Mark J Mannis; Edward J Holland; Mark Gorovoy; Sadeer B Hannush; John E Bokosky; James W Caudill
Journal:  JAMA Ophthalmol       Date:  2013-05       Impact factor: 7.389

6.  Donor organ cultured corneal tissue selection before penetrating keratoplasty.

Authors:  V M Borderie; S Scheer; O Touzeau; F Vedie; S Carvajal-Gonzalez; L Laroche
Journal:  Br J Ophthalmol       Date:  1998-04       Impact factor: 4.638

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.