Literature DB >> 8227387

Application of intracoronary ultrasonography in the study of coronary artery pathophysiology.

Q Rasheed1, J M Hodgson.   

Abstract

Coronary endothelial function, arterial distensibility, and elastic recoil were assessed in various groups of patients using intracoronary ultrasonic (ICUS) imaging. We found evidence of endothelial dysfunction in patients with risk factors for coronary artery disease even before atherosclerosis could be detected angiographically or with sensitive ICUS imaging. There was marked reduction of arterial distensibility in atherosclerotic arterial segments even with minor disease. Distensibility was partially restored in lesions following coronary balloon angioplasty (PTCA) or directional atherectomy (DCA). We also noted significantly greater elastic recoil following PTCA in soft lesions compared with hard lesions. We conclude that the use of ICUS imaging in cardiac catheterization laboratory provides useful information regarding various physiologic parameters. This capability will add new dimensions to the evaluation and management of patients with coronary artery disease.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8227387     DOI: 10.1002/jcu.1870210904

Source DB:  PubMed          Journal:  J Clin Ultrasound        ISSN: 0091-2751            Impact factor:   0.910


  6 in total

Review 1.  Quantitative measurements in IVUS images.

Authors:  J Dijkstra; G Koning; J H Reiber
Journal:  Int J Card Imaging       Date:  1999-12

2.  Advanced contour detection for three-dimensional intracoronary ultrasound: a validation--in vitro and in vivo.

Authors:  Gerhard Koning; Jouke Dijkstra; Clemens von Birgelen; Joan C Tuinenburg; Jean Brunette; Jean-Claude Tardif; Pranobe W Oemrawsingh; Christian Sieling; Sören Melsa; Johan H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2002-08       Impact factor: 2.357

3.  Abdominal Aortic Hemodynamics in Intermittent Claudication Patients at Rest and during Dynamic Pedaling Exercise.

Authors:  Christopher P Cheng; Charles A Taylor; Ronald L Dalman
Journal:  Ann Vasc Surg       Date:  2015-08-24       Impact factor: 1.466

Review 4.  Intravascular ultrasound imaging of peripheral arteries as an adjunct to balloon angioplasty and atherectomy.

Authors:  Y Korogi; T Hirai; M Takahashi
Journal:  Cardiovasc Intervent Radiol       Date:  1996 Jan-Feb       Impact factor: 2.740

5.  Time dependent changes of arterial distensibility induced by cholesterol and balloon injury in rabbits: an in vivo intravascular ultrasound study.

Authors:  Michael Ribbing; Anja Dorszewski; Holger Reinecke; Günter Breithardt; Sebastian Kerber
Journal:  Int J Cardiovasc Imaging       Date:  2002-12       Impact factor: 2.357

6.  Nitric oxide function in atherosclerosis.

Authors:  K E Matthys; H Bult
Journal:  Mediators Inflamm       Date:  1997       Impact factor: 4.711

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.