Literature DB >> 10768745

Quantitative measurements in IVUS images.

J Dijkstra1, G Koning, J H Reiber.   

Abstract

IntraVascular UltraSound (IVUS) is a catheter-based technique which provides real-time high resolution tomographic images of both the lumen and arterial wall of a coronary segment, this in contrast to X-ray arteriography that provides a shadow image (luminogram) of the entire lumen. Nowadays the lumen and vessel parameters are measured manually, which is very time consuming and suffers from high inter- and intra-obser variability. With the continuing improvement in IVUS imaging, it is now feasible to develop and clinically apply automated methods of three-dimensional quantitative analysis of the coronary vessel morphology in an objective and reproducible way with automated contour detection techniques (QCU). Quantification, in 2D and 3D, as well as volume rendering for visualization of the IVUS images requires segmentation of the images (contour detection). The 3D contour detection system described in this article is based on the combination of contour detection in the transversal and sagital view. This article provides some of the basic principles of IVUS, the IVUS image quantification, the three-dimensional reconstruction and the contour detection and quantification in three-dimensional IVUS images.

Mesh:

Year:  1999        PMID: 10768745     DOI: 10.1023/a:1006334517720

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  14 in total

1.  Segmentation of intravascular ultrasound images: a knowledge-based approach.

Authors:  M Sonka; X Zhang; M Siebes; M S Bissing; S C Dejong; S M Collins; C R McKay
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

2.  Intravascular ultrasound. A fantastic voyage.

Authors:  J M Tobis
Journal:  Circulation       Date:  1991-11       Impact factor: 29.690

3.  Optimized expansion of the Wallstent compared with the Palmaz-Schatz stent: on-line observations with two- and three-dimensional intracoronary ultrasound after angiographic guidance.

Authors:  C von Birgelen; R Gil; P Ruygrok; F Prati; C Di Mario; W J van der Giessen; P J de Feyter; P W Serruys
Journal:  Am Heart J       Date:  1996-06       Impact factor: 4.749

4.  Usefulness of three-dimensional reconstruction for interpretation and quantitative analysis of intracoronary ultrasound during stent deployment.

Authors:  R Gil; C von Birgelen; F Prati; C Di Mario; J Ligthart; P W Serruys
Journal:  Am J Cardiol       Date:  1996-04-01       Impact factor: 2.778

5.  Morphometric analysis in three-dimensional intracoronary ultrasound: an in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaque.

Authors:  C von Birgelen; C Di Mario; W Li; J C Schuurbiers; C J Slager; P J de Feyter; J R Roelandt; P W Serruys
Journal:  Am Heart J       Date:  1996-09       Impact factor: 4.749

Review 6.  High-frequency intracoronary ultrasound imaging.

Authors:  F S Foster; D A Knapik; J C Machado; L K Ryan; S E Nissen
Journal:  Semin Interv Cardiol       Date:  1997-03

Review 7.  Three-dimensional reconstruction of intracoronary ultrasound images. Rationale, approaches, problems, and directions.

Authors:  J R Roelandt; C di Mario; N G Pandian; L Wenguang; D Keane; C J Slager; P J de Feyter; P W Serruys
Journal:  Circulation       Date:  1994-08       Impact factor: 29.690

8.  Three-dimensional reconstruction of human coronary and peripheral arteries from images recorded during two-dimensional intravascular ultrasound examination.

Authors:  K Rosenfield; D W Losordo; K Ramaswamy; J O Pastore; R E Langevin; S Razvi; B D Kosowsky; J M Isner
Journal:  Circulation       Date:  1991-11       Impact factor: 29.690

9.  Intravascular ultrasound assessment of lumen size and wall morphology in normal subjects and patients with coronary artery disease.

Authors:  S E Nissen; J C Gurley; C L Grines; D C Booth; R McClure; M Berk; C Fischer; A N DeMaria
Journal:  Circulation       Date:  1991-09       Impact factor: 29.690

10.  Application of intracoronary ultrasonography in the study of coronary artery pathophysiology.

Authors:  Q Rasheed; J M Hodgson
Journal:  J Clin Ultrasound       Date:  1993 Nov-Dec       Impact factor: 0.910

View more
  6 in total

1.  Vasa vasorum imaging: a new window to the clinical detection of vulnerable atherosclerotic plaques.

Authors:  Stéphane Carlier; Ioannis A Kakadiaris; Nabil Dib; Manolis Vavuranakis; Sean M O'Malley; Khawar Gul; Craig J Hartley; Ralph Metcalfe; Roxana Mehran; Christodoulos Stefanadis; Erling Falk; Gregg Stone; Martin Leon; Morteza Naghavi
Journal:  Curr Atheroscler Rep       Date:  2005-03       Impact factor: 5.113

2.  Impact of analyzing less image frames per segment for radiofrequency-based volumetric intravascular ultrasound measurements in mild-to-moderate coronary atherosclerosis.

Authors:  Jennifer Huisman; Marc Hartmann; Eline S K Mattern; Gary S Mintz; Mounir W Z Basalus; Gert K van Houwelingen; Patrick M J Verhorst; Clemens von Birgelen
Journal:  Int J Cardiovasc Imaging       Date:  2010-02-27       Impact factor: 2.357

3.  Graph-based IVUS segmentation with efficient computer-aided refinement.

Authors:  Shanhui Sun; Milan Sonka; Reinhard R Beichel
Journal:  IEEE Trans Med Imaging       Date:  2013-04-30       Impact factor: 10.048

4.  Detection of coronary plaques using MR coronary vessel wall imaging: validation of findings with intravascular ultrasound.

Authors:  Suzanne Gerretsen; Alfons G Kessels; Patty J Nelemans; Jouke Dijkstra; Johan H C Reiber; Rob J van der Geest; Marcus Katoh; Johannes Waltenberger; Jos M A van Engelshoven; Rene M Botnar; M Eline Kooi; Tim Leiner
Journal:  Eur Radiol       Date:  2012-07-11       Impact factor: 5.315

5.  Segmenting breast cancerous regions in thermal images using fuzzy active contours.

Authors:  Hossein Ghayoumi Zadeh; Javad Haddadnia; Omid Rahmani Seryasat; Sayed Mohammad Mostafavi Isfahani
Journal:  EXCLI J       Date:  2016-08-26       Impact factor: 4.068

Review 6.  The Evolution of Data Fusion Methodologies Developed to Reconstruct Coronary Artery Geometry From Intravascular Imaging and Coronary Angiography Data: A Comprehensive Review.

Authors:  Yakup Kilic; Hannah Safi; Retesh Bajaj; Patrick W Serruys; Pieter Kitslaar; Anantharaman Ramasamy; Vincenzo Tufaro; Yoshinobu Onuma; Anthony Mathur; Ryo Torii; Andreas Baumbach; Christos V Bourantas
Journal:  Front Cardiovasc Med       Date:  2020-03-31
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.