Sources of error in quantitative coronary angiography.

D M Herrington1, M Siebes, G D Walford.   

Abstract

Many studies have reported the accuracy of quantitative coronary angiography (QCA) based on experiments using moderated-size phantoms imaged under unrealistic radiographic conditions. However, these observations may not be generalizable to the setting of clinical angiography. To determine QCA accuracy in a realistic radiographic setting and evaluate the impact of the x-ray system line spread function, plexiglass phantoms were imaged inside and out of a human thorax. A realistic radiographic background was associated with a 38% increase in variability of results (p < 0.05). Low concentrations of contrast and large image intensifier input screens were associated with significantly larger errors and variability in results (p < 0.05). There was a systematic overestimation of diameter in the smallest phantom. A mathematical model of the x-ray line spread function was developed that explains the observed overestimation of the smallest phantom and provide a rational approach for correction of the line spread function for QCA. Many factors encountered in clinical coronary angiography such as nonuniform radiographic background, low concentrations of contrast, and small vessel diameters have a significant adverse impact on the accuracy and/or variability of gradient-based edge detection QCA systems.

Entities:  

Mesh:

Year:  1993        PMID: 8221856     DOI: 10.1002/ccd.1810290416

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  7 in total

1.  Validation of an accurate method for three-dimensional reconstruction and quantitative assessment of volumes, lengths and diameters of coronary vascular branches and segments from biplane angiographic projections.

Authors:  E Wellnhofer; A Wahle; I Mugaragu; J Gross; H Oswald; E Fleck
Journal:  Int J Card Imaging       Date:  1999-10

2.  Adaptive edge localisation approach for quantitative coronary analysis.

Authors:  A S Al-Fahoum
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602

Review 3.  Novel QCA methodologies and angiographic scores.

Authors:  Vivian G Ng; Alexandra J Lansky
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-20       Impact factor: 2.357

4.  An analogue laser optical disc in comparison with cinefilm for visual analysis of coronary narrowings before and after coronary angioplasty.

Authors:  S A Chamuleau; J J Piek; W B Hanekamp; Y E Appelman; K T Koch; R J Peters; W E Kok; G Bloemhard; G A la Rivière; G K David
Journal:  Int J Card Imaging       Date:  1998-02

5.  Comparison of QCA systems.

Authors:  U Dietz; H J Rupprecht; R Brennecke; H P Fritsch; J Woltmann; S Blankenberg; J Meyer
Journal:  Int J Card Imaging       Date:  1997-08

6.  Comparative cath-lab assessment of coronary stenosis by radiology technician, junior and senior interventional cardiologist in patients treated with coronary angioplasty.

Authors:  Natale Daniele Brunetti; Felice Delli Carri; Maria Assunta Ruggiero; Andrea Cuculo; Antonio Ruggiero; Luigi Ziccardi; Luisa De Gennaro; Matteo Di Biase
Journal:  Interv Med Appl Sci       Date:  2014-03-14

7.  Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  J Med Imaging (Bellingham)       Date:  2014-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.