Literature DB >> 8208590

Evaluation of the interrupter technique for the use of assessing airway obstruction in children.

E R Carter1, A A Stecenko, B H Pollock, M J Jaeger.   

Abstract

The purpose of this study was to determine if the interrupter technique, a noninvasive method for measuring airflow resistance, could be used to assess airway obstruction in children. In 107 children (74 with asthma, 12 with cystic fibrosis, and 21 without lung disease) conductance (mostly of airways) measured with the interrupter technique (Gint) was correlated with both forced expiratory volume in 1 second (FEV1) and the forced expired flow rate between 25% and 75% of vital capacity (FEF25-75). In addition, 17 children with significant airway obstruction due to asthma also had airway resistance measured by body plethysmography (R(aw)) before and after treatment. Resistance and conductance measurements made with the interrupter technique were subdivided into inspiratory (Rint-insp, Gint-insp) and expiratory (Rint-exp, Gint-exp) values. In the 107 children, a high degree of linear correlation was found between Gint and FEV1; for Gint-exp, r = 0.77 (P < 0.001), and for Gint-insp, r = 0.76 (P < 0.001). There was also good linear correlation between Gint and FEF25-75; for Gint-exp, r = 0.70 (P < 0.001), and for Gint-insp, r = 0.67 (P < 0.001). In the 17 asthmatic children who were tested before and after treatment of their airway obstruction, Rint correlated highly with R(aw); for Rint-exp, r = 0.91 (P < 0.001), and for Rint-insp, r = 0.83 (P < 0.001). The pre- to post-treatment changes in Rint and R(aw) were similar.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1994        PMID: 8208590     DOI: 10.1002/ppul.1950170402

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  6 in total

1.  Airway resistance measured by the interrupter technique: normative data for 2-10 year olds of three ethnicities.

Authors:  S A McKenzie; E Chan; I Dundas; P D Bridge; C S Pao; M Mylonopoulou; M J R Healy
Journal:  Arch Dis Child       Date:  2002-09       Impact factor: 3.791

2.  Short and long term variability of the interrupter technique under field and standardised conditions in 3-6 year old children.

Authors:  R M J Beelen; H A Smit; R T van Strien; L P Koopman; J E Brussee; B Brunekreef; J Gerritsen; P J F M Merkus
Journal:  Thorax       Date:  2003-09       Impact factor: 9.139

Review 3.  Advancements in Methods and Camera-Based Sensors for the Quantification of Respiration.

Authors:  Haythem Rehouma; Rita Noumeir; Sandrine Essouri; Philippe Jouvet
Journal:  Sensors (Basel)       Date:  2020-12-17       Impact factor: 3.576

4.  Reference values of interrupter respiratory resistance in healthy preschool white children.

Authors:  E Lombardi; P D Sly; G Concutelli; E Novembre; G Veneruso; G Frongia; R Bernardini; A Vierucci
Journal:  Thorax       Date:  2001-09       Impact factor: 9.139

5.  Plethysmograph and interrupter resistance measurements in prematurely born young children.

Authors:  M R Thomas; G F Rafferty; R Blowes; J L Peacock; N Marlow; S Calvert; A Milner; A Greenough
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2005-10-20       Impact factor: 5.747

6.  Asthma in intellectual disability: are we managing our patients appropriately?

Authors:  Sharon Davis
Journal:  Breathe (Sheff)       Date:  2016-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.