Literature DB >> 1325973

Early clinical experience with hydroxyapatite-coated femoral implants.

J A D'Antonio1, W N Capello, O D Crothers, W L Jaffe, M T Manley.   

Abstract

As part of a multi-center study, 238 titanium stems that were proximally coated with hydroxyapatite were implanted in 220 patients between January 1988 and December 1989. Ninety-two of these stems in eighty-three patients had a minimum of two years of follow-up, including analysis of the clinical and radiographic data. Clinically, the patients were essentially pain-free before six months and had a low (4 per cent) prevalence of pain in the thigh and a very high composite Harris hip-score (mean, 95 points) at two years. Radiographically, subsidence was detected in 8 per cent of the implants; no implant had more than three millimeters of subsidence. Radiolucencies were characteristically seen around the uncoated distal part of the stem, in 70 per cent of the implants. Contrastingly, radiolucencies were rare in the hydroxyapatite-coated proximal zones and were most often found anteriorly, in only 5 per cent of the implants. Areas of increased formation of cancellous bone were seen beneath femoral cortical bone at the interface between the hydroxyapatite-coated and uncoated parts of the stem, in 67 per cent of the implants. Calcar resorption was found in 49 per cent of the implants. Cortical thickening was present in 17 per cent of the implants at the uncoated distal part of the stem. Two of the 238 femoral implants were revised: one because of infection and one because of aseptic loosening associated with non-union of a subtrochanteric osteotomy.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1325973

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  6 in total

1.  [Results of implantation of uncemented porous metal hip prostheses].

Authors:  M Runkel; U Jaeger; K Wenda; J Degreif; L Rudig; G Ritter
Journal:  Unfallchirurgie       Date:  1994-04

2.  The effect of hydroxyapatite coating on the fixation of hip prostheses. A comparison of clinical and radiographic results of hip replacement in a matched-pair study.

Authors:  J Huracek; P Spirig
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

3.  Late remodeling around a proximally HA-coated tapered titanium femoral component.

Authors:  William N Capello; James A D'Antonio; Rudolph G Geesink; Judy R Feinberg; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2008-10-11       Impact factor: 4.176

4.  An in vivo evaluation of bone response to three implant surfaces using a rabbit intramedullary rod model.

Authors:  Juan C Hermida; Arnie Bergula; Fred Dimaano; Monica Hawkins; Clifford W Colwell; Darryl D D'Lima
Journal:  J Orthop Surg Res       Date:  2010-08-16       Impact factor: 2.359

5.  Seven-year results of a tapered, titanium, hydroxyapatite-coated cementless femoral stem in primary total hip arthroplasty.

Authors:  Jin-Ho Cho; Jonathan P Garino; Suk-Kyu Choo; Kye-Young Han; Jung-Hoon Kim; Hyoung-Keun Oh
Journal:  Clin Orthop Surg       Date:  2010-11-05

6.  5-year clinical and radiographic follow-up of the uncemented Symax hip stem in an international study.

Authors:  Dennis Silvester Maria Gerardus Kruijntjens; Per Kjaersgaard-Andersen; Peter Revald; Jane Schwartz Leonhardt; Jacobus Johannes Chris Arts; René Hendrikus Maria Ten Broeke
Journal:  J Orthop Surg Res       Date:  2018-07-31       Impact factor: 2.359

  6 in total