Literature DB >> 8195370

Analysis of western blotting (immunoblotting) technique in diagnosis of congenital syphilis.

M P Meyer1, T Eddy, R E Baughn.   

Abstract

The diagnosis of congenital syphilis in apparently healthy infants continues to be problematic. Immunoglobulin M antibodies specific for a subset of Treponema pallidum antigens have been detected by Western blotting (immunoblotting). In the present study we investigated the sensitivity and specificity of this method. We tested 26 infants aged 0 to 4 months who fulfilled the accepted criteria for the diagnosis of congenital syphilis. There were 14 symptomatic infants. Sera from 13 of these infants were positive for the 47-kDa treponemal antigen (92% sensitivity). The remaining 12 infants were clinically asymptomatic when tested at birth but subsequently displayed features consistent with the disease. Reactive blots (antibodies to the 47- and/or the 15-kDa antigens) were noted in 10 of the 12 infants (83% sensitivity). Thirty infants whose mothers had syphilis were monitored and shown to be uninfected. Nonreactive blots were seen in sera from 27 infants, while sera from 3 older infants had false-positive tests (90% specificity). The Western blotting technique is sensitive (even in the diagnosis of clinically inapparent cases) and, in the absence of immunoglobulin M rheumatoid factor, is a useful confirmatory test for congenital syphilis.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8195370      PMCID: PMC263098          DOI: 10.1128/jcm.32.3.629-633.1994

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  12 in total

1.  Evaluation and treatment of congenital syphilis.

Authors:  M K Ikeda; H B Jenson
Journal:  J Pediatr       Date:  1990-12       Impact factor: 4.406

Review 2.  The FTA-ABS (IgM) test for neonatal congenital syphilis: A critical review.

Authors:  R E Kaufman; D C Olansky; P J Wiesner
Journal:  J Am Vener Dis Assoc       Date:  1974-12

3.  Isolation and preliminary characterization of circulating immune complexes from rabbits with experimental syphilis.

Authors:  R E Baughn; D M Musher
Journal:  Infect Immun       Date:  1983-11       Impact factor: 3.441

4.  Questionnaire survey of reported early congenital syphilis: problems in diagnosis, prevention, and treatment.

Authors:  R E Kaufman; O G Jones; J H Blount; P J Wiesner
Journal:  Sex Transm Dis       Date:  1977 Oct-Dec       Impact factor: 2.830

5.  Evaluation of immunoglobulin M western blot analysis in the diagnosis of congenital syphilis.

Authors:  L L Lewis; L H Taber; R E Baughn
Journal:  J Clin Microbiol       Date:  1990-02       Impact factor: 5.948

6.  Radioimmunoassays for the detection of antibodies to treponemal polypeptide antigens in serum.

Authors:  R E Baughn; D M Musher
Journal:  J Clin Microbiol       Date:  1985-06       Impact factor: 5.948

7.  Congenital syphilis: a diagnostic and therapeutic dilemma.

Authors:  G Srinivasan; R S Ramamurthy; A Bharathi; S Voora; R S Pildes
Journal:  Pediatr Infect Dis       Date:  1983 Nov-Dec

8.  Evaluation of a Treponema pallidum western immunoblot assay as a confirmatory test for syphilis.

Authors:  R E Byrne; S Laska; M Bell; D Larson; J Phillips; J Todd
Journal:  J Clin Microbiol       Date:  1992-01       Impact factor: 5.948

9.  Molecular analysis of the fetal IgM response to Treponema pallidum antigens: implications for improved serodiagnosis of congenital syphilis.

Authors:  P J Sánchez; G H McCracken; G D Wendel; K Olsen; N Threlkeld; M V Norgard
Journal:  J Infect Dis       Date:  1989-03       Impact factor: 5.226

10.  Diagnosis of congenital syphilis by combining Treponema pallidum-specific IgM detection with immunofluorescent antigen detection for T. pallidum.

Authors:  K Bromberg; S Rawstron; G Tannis
Journal:  J Infect Dis       Date:  1993-07       Impact factor: 5.226

View more
  4 in total

1.  Western immunoblotting with five Treponema pallidum recombinant antigens for serologic diagnosis of syphilis.

Authors:  V Sambri; A Marangoni; C Eyer; C Reichhuber; E Soutschek; M Negosanti; A D'Antuono; R Cevenini
Journal:  Clin Diagn Lab Immunol       Date:  2001-05

Review 2.  Laboratory diagnosis and interpretation of tests for syphilis.

Authors:  S A Larsen; B M Steiner; A H Rudolph
Journal:  Clin Microbiol Rev       Date:  1995-01       Impact factor: 26.132

3.  Recombinant antigen-based enzyme immunoassay for screening of Treponema pallidum antibodies in blood bank routine.

Authors:  M Zrein; I Maure; F Boursier; L Soufflet
Journal:  J Clin Microbiol       Date:  1995-03       Impact factor: 5.948

4.  Evaluation of the BioPlex 2200 syphilis system as a first-line method of reverse-sequence screening for syphilis diagnosis.

Authors:  Antonella Marangoni; Paola Nardini; Claudio Foschi; Alessandra Moroni; Antonietta D'Antuono; Letizia Bacchi Reggiani; Roberto Cevenini
Journal:  Clin Vaccine Immunol       Date:  2013-05-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.