Recombinant antigen-based enzyme immunoassay for screening of Treponema pallidum antibodies in blood bank routine.

M Zrein1, I Maure, F Boursier, L Soufflet.   

Abstract

This work reports a comparison of an enzyme immunoassay (EIA) using two major Treponema pallidum recombinant antigens with a T. pallidum hemagglutination (TPHA) assay and a nontreponemal Venereal Disease Reference Laboratory (VDRL) test. A total of 1,822 normal donor serum samples was tested for cardiolipin and T. pallidum antibodies, respectively, by the VDRL assay and EIA. Among these samples, 440 were further tested by TPHA technology. Four samples were found positive by EIA, while all were reported to be negative by both TPHA and VDRL routine assays. Subsequent testing of EIA-positive samples confirmed 100% (four of four samples) and 25% (one of four samples) positive results, respectively, by immunofluorescence assay and a Western blot (immunoblot) syphilis kit. The sensitivity of the recombinant EIA was estimated at virtually 100% with a reference panel of 50 syphilitic samples. According to this study, the newly developed EIA kit shows 100% sensitivity combined to a specificity greater than 99.8% for detecting treponemal immunoglobulin G antibodies in blood bank syphilis screening.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7751351      PMCID: PMC227984          DOI: 10.1128/jcm.33.3.525-527.1995

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  17 in total

Review 1.  Acquired syphilis in adults.

Authors:  E W Hook; C M Marra
Journal:  N Engl J Med       Date:  1992-04-16       Impact factor: 91.245

2.  False-positive reactions in the rapid plasma reagin-card, fluorescent treponemal antibody-absorbed, and hemagglutination treponemal syphilis serology tests.

Authors:  C R Peter; M A Thompson; D L Wilson
Journal:  J Clin Microbiol       Date:  1979-03       Impact factor: 5.948

3.  Biological false positive serological tests for syphilis among drug addicts.

Authors:  R E Kaufman; S Weiss; J D Moore; V Falcone; P J Wiesner
Journal:  Br J Vener Dis       Date:  1974-10

4.  False-negative syphilis screening: the prozone phenomenon, nonimmune hydrops, and diagnosis of syphilis during pregnancy.

Authors:  K Berkowitz; L Baxi; H E Fox
Journal:  Am J Obstet Gynecol       Date:  1990-09       Impact factor: 8.661

5.  Analysis of western blotting (immunoblotting) technique in diagnosis of congenital syphilis.

Authors:  M P Meyer; T Eddy; R E Baughn
Journal:  J Clin Microbiol       Date:  1994-03       Impact factor: 5.948

6.  Evaluation of the Captia enzyme immunoassays for detection of immunoglobulins G and M to Treponema pallidum in syphilis.

Authors:  J C Lefevre; M A Bertrand; R Bauriaud
Journal:  J Clin Microbiol       Date:  1990-08       Impact factor: 5.948

7.  Identification of Treponema pallidum antigens: comparison with a nonpathogenic treponeme.

Authors:  S A Lukehart; S A Baker-Zander; E R Gubish
Journal:  J Immunol       Date:  1982-08       Impact factor: 5.422

8.  Humoral immune response in experimental syphilis to polypeptides of Treponema pallidum.

Authors:  P A Hanff; N H Bishop; J N Miller; M A Lovett
Journal:  J Immunol       Date:  1983-10       Impact factor: 5.422

9.  Specificity, sensitivity, and reproducibility among the fluorescent treponemal antibody-absorption test, the microhemagglutination assay for Treponema pallidum antibodies, and the hemagglutination treponemal test for syphilis.

Authors:  S A Larsen; E A Hambie; D E Pettit; M W Perryman; S J Kraus
Journal:  J Clin Microbiol       Date:  1981-10       Impact factor: 5.948

10.  Antigenic complexity of Treponema pallidum: antigenicity and surface localization of major polypeptides.

Authors:  S J Norris; S Sell
Journal:  J Immunol       Date:  1984-11       Impact factor: 5.422

View more
  16 in total

1.  Validation of the INNO-LIA syphilis kit as a confirmatory assay for Treponema pallidum antibodies.

Authors:  A Ebel; L Vanneste; M Cardinaels; E Sablon; I Samson; K De Bosschere; F Hulstaert; M Zrein
Journal:  J Clin Microbiol       Date:  2000-01       Impact factor: 5.948

2.  Evaluation of a new particle gel immunoassay for determination of antibodies against Treponema pallidum.

Authors:  Bruno L Schmidt
Journal:  J Clin Microbiol       Date:  2004-06       Impact factor: 5.948

3.  Evaluation of LIAISON Treponema Screen, a novel recombinant antigen-based chemiluminescence immunoassay for laboratory diagnosis of syphilis.

Authors:  Antonella Marangoni; Vittorio Sambri; Silvia Accardo; Francesca Cavrini; Antonietta D'Antuono; Alessandra Moroni; Elisa Storni; Roberto Cevenini
Journal:  Clin Diagn Lab Immunol       Date:  2005-10

4.  Western immunoblotting with five Treponema pallidum recombinant antigens for serologic diagnosis of syphilis.

Authors:  V Sambri; A Marangoni; C Eyer; C Reichhuber; E Soutschek; M Negosanti; A D'Antuono; R Cevenini
Journal:  Clin Diagn Lab Immunol       Date:  2001-05

5.  Performance of CAPTIA SelectSyph-G enzyme-linked immunosorbent assay in syphilis testing of a high-risk population: analysis of discordant results.

Authors:  Vladana Woznicová; Zuzana Valisová
Journal:  J Clin Microbiol       Date:  2007-04-18       Impact factor: 5.948

6.  Evaluation of a new competitive immunoassay (BioElisa Syphilis) for screening for Treponema pallidum antibodies at various stages of syphilis.

Authors:  A Ebel; L Bachelart; J M Alonso
Journal:  J Clin Microbiol       Date:  1998-02       Impact factor: 5.948

7.  Establishment and Evaluation of a One-Step Microplate Chemiluminescence Immunoassay to Detect IgG Antibody Against Treponema Pallidum.

Authors:  Lijuan Liu; Yuling Xie; Zhenxian Dai; Chuanshang Zhuo; Yushui Wu
Journal:  J Clin Lab Anal       Date:  2014-10-02       Impact factor: 2.352

8.  Novel recombinant-antigen enzyme immunoassay for serological diagnosis of syphilis.

Authors:  H Young; A Moyes; L Seagar; A McMillan
Journal:  J Clin Microbiol       Date:  1998-04       Impact factor: 5.948

9.  Laboratory diagnosis of syphilis with automated immunoassays.

Authors:  Antonella Marangoni; Alessandra Moroni; Silvia Accardo; Roberto Cevenini
Journal:  J Clin Lab Anal       Date:  2009       Impact factor: 2.352

10.  Evaluation of the BioPlex 2200 syphilis system as a first-line method of reverse-sequence screening for syphilis diagnosis.

Authors:  Antonella Marangoni; Paola Nardini; Claudio Foschi; Alessandra Moroni; Antonietta D'Antuono; Letizia Bacchi Reggiani; Roberto Cevenini
Journal:  Clin Vaccine Immunol       Date:  2013-05-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.