Literature DB >> 8187282

In vivo myocardial kinetics of air-filled albumin microbubbles during myocardial contrast echocardiography. Comparison with radiolabeled red blood cells.

A R Jayaweera1, N Edwards, W P Glasheen, F S Villanueva, R D Abbott, S Kaul.   

Abstract

Myocardial contrast echocardiography (MCE) is a new technique for assessing myocardial perfusion that uses intracoronary injections of microbubbles of air. Because these microbubbles have a mean diameter of 4.3 +/- 0.3 microns and an intravascular rheology similar to that of red blood cells (RBCs), we hypothesized that their mean myocardial transit rates recorded on echocardiography would provide an estimation of regional myocardial blood flow in the in vivo beating heart. Accordingly, blood flow to the left anterior descending coronary artery (LAD) of 12 open-chest anesthetized dogs (group I) was adjusted to 4 to 6 flows (total of 60 flows), and microbubbles and radiolabeled RBCs were injected into the LAD in a random order at each stage. The mean myocardial RBC transit rates were measured by fitting a gamma-variate function to time-activity plots generated by placing a miniature CsI2 probe over the anterior surface of the heart, and the mean myocardial microbubble transit rates were measured from time-intensity plots derived from off-line analysis of MCE images obtained during the injection of microbubbles. An excellent correlation was noted between flow (measured with an extracorporeal electromagnetic flow probe) and mean myocardial RBC transit rate (y = 2.83 x 10(-3)x + 0.01, r = .96, SEE = 0.02, P < .001). A close correlation was also noted between mean RBC and microbubble myocardial transit rates (y = 1.01x + 0.01, r = .89, SEE = 0.02, P < .001). Despite its theoretical advantages, a lagged normal density function did not provide a better fit to the MCE data than the gamma-variate function.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8187282     DOI: 10.1161/01.res.74.6.1157

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  54 in total

Review 1.  Section 8--clinical relevance. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 2.  Section 6--mechanical bioeffects in the presence of gas-carrier ultrasound contrast agents. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 3.  Section 7--discussion of the mechanical index and other exposure parameters. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 4.  Section 4--bioeffects in tissues with gas bodies. American Institute of Ultrasound in Medicine.

Authors: 
Journal:  J Ultrasound Med       Date:  2000-02       Impact factor: 2.153

Review 5.  The role of capillaries in determining coronary blood flow reserve: Implications for stress-induced reversible perfusion defects.

Authors:  S Kaul
Journal:  J Nucl Cardiol       Date:  2001 Nov-Dec       Impact factor: 5.952

Review 6.  Imaging myocardial metabolic remodeling.

Authors:  Robert J Gropler; Rob S B Beanlands; Vasken Dilsizian; E Douglas Lewandowski; Flordeliza S Villanueva; Maria Cecilia Ziadi
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

7.  [Quantification of tissue perfusion with novel ultrasound methods].

Authors:  M Krix; H-U Kauczor; S Delorme
Journal:  Radiologe       Date:  2003-10       Impact factor: 0.635

Review 8.  Molecular imaging with contrast enhanced ultrasound.

Authors:  Scott M Chadderdon; Sanjiv Kaul
Journal:  J Nucl Cardiol       Date:  2010-08       Impact factor: 5.952

Review 9.  Echocardiographic insights into regional flow-function relationships in coronary artery disease.

Authors:  Sanjiv Kaul
Journal:  J Nucl Cardiol       Date:  2005 Mar-Apr       Impact factor: 5.952

10.  Effects of high-fat diet and losartan on renal cortical blood flow using contrast ultrasound imaging.

Authors:  Anne-Emilie Declèves; Joshua J Rychak; Dan J Smith; Kumar Sharma
Journal:  Am J Physiol Renal Physiol       Date:  2013-09-18
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.