Literature DB >> 8166276

Spatiotemporal characteristics of physiological gastroesophageal reflux.

B L Weusten1, L M Akkermans, G P vanBerge-Henegouwen, A J Smout.   

Abstract

Recent technological developments have made it possible to measure intraluminal pH simultaneously at multiple sites using one single small-caliber catheter. The aim of this study was to investigate the dynamics of physiological gastroesophageal reflux in eight ambulatory healthy volunteers (age 21-51 yr). Esophageal pH was recorded for 24 h at 3, 6, 9, 12 and 15 cm from the lower esophageal sphincter (LES), using an 8-Fr catheter containing five ion-sensitive field effect transistor (ISFET) pH transducers and a digital data logger. Signals were sampled at a rate of 4 Hz. Automated analysis included determination of the extent of the reflux (cm above LES) and calculation of the velocity of the advance of the pH front from the LES (ascending velocity), minimum pH reached, and duration of all individual reflux episodes at different segments in the esophagus. The reflux time and the number of reflux episodes/24 h showed a gradual decrease from the distal to the proximal sensor (mean +/- SE: 4.4 +/- 0.8 to 0.9 +/- 0.2% and 46 +/- 7.6 to 11 +/- 1.9, respectively). Of all reflux episodes 23% did not reach the sensor at 6 cm above the LES, and only 25% reached the most proximal sensor. Characteristically, acid refluxed rapidly (velocity 0.4-2.4 cm/s) and was cleared in a stepwise fashion. Reflux episodes of long duration at the distal sensor reached high levels in the esophagus (P < 0.001). It was concluded that ambulatory multichannel esophageal pH monitoring using ISFET technology is a valuable tool for studies on the spatio-temporal characteristics of gastroesophageal reflux.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8166276     DOI: 10.1152/ajpgi.1994.266.3.G357

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  18 in total

1.  Capsule pH monitoring: is wireless more?

Authors:  R H Holloway
Journal:  Gut       Date:  2005-12       Impact factor: 23.059

2.  Acid reflux event detection using the Bravo wireless versus the Slimline catheter pH systems: why are the numbers so different?

Authors:  J E Pandolfino; Q Zhang; M A Schreiner; S Ghosh; M P Roth; P J Kahrilas
Journal:  Gut       Date:  2005-05-28       Impact factor: 23.059

3.  Relevance of volume and proximal extent of reflux in gastro-oesophageal reflux disease.

Authors:  D Sifrim
Journal:  Gut       Date:  2005-02       Impact factor: 23.059

4.  Electrophysiological characterization of vagal afferents relevant to mucosal nociception in the rat upper oesophagus.

Authors:  J K M Lennerz; C Dentsch; N Bernardini; T Hummel; W L Neuhuber; P W Reeh
Journal:  J Physiol       Date:  2007-05-03       Impact factor: 5.182

5.  A new technique for measurement of pharyngeal pH: normal values and discriminating pH threshold.

Authors:  S Ayazi; J C Lipham; J A Hagen; A L Tang; J Zehetner; J M Leers; A Oezcelik; E Abate; F Banki; S R DeMeester; T R DeMeester
Journal:  J Gastrointest Surg       Date:  2009-05-07       Impact factor: 3.452

6.  Patterns of gas and liquid reflux during transient lower oesophageal sphincter relaxation: a study using intraluminal electrical impedance.

Authors:  D Sifrim; J Silny; R H Holloway; J J Janssens
Journal:  Gut       Date:  1999-01       Impact factor: 23.059

7.  Effect of different pH criteria on dual-sensor pH monitoring in the evaluation of supraesophageal gastric reflux in children.

Authors:  Eric Chiou; Rachel Rosen; Samuel Nurko
Journal:  J Pediatr Gastroenterol Nutr       Date:  2011-04       Impact factor: 2.839

8.  Proximal sensor data from routine dual-sensor esophageal pH monitoring is often inaccurate.

Authors:  Matt McCollough; Abdul Jabbar; Robert Cacchione; Jeff W Allen; Steve Harrell; John M Wo
Journal:  Dig Dis Sci       Date:  2004-10       Impact factor: 3.199

Review 9.  Gastro-oesophageal reflux monitoring: review and consensus report on detection and definitions of acid, non-acid, and gas reflux.

Authors:  D Sifrim; D Castell; J Dent; P J Kahrilas
Journal:  Gut       Date:  2004-07       Impact factor: 23.059

10.  Ambulatory pH: monitoring with a wireless system.

Authors:  J H Schneider; K M Kramer; A Königsrainer; F A Granderath
Journal:  Surg Endosc       Date:  2007-05-05       Impact factor: 4.584

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.