Literature DB >> 814819

Valve implants in filtering surgery.

T Krupin, S M Podos, B Becker, J B Newkirk.   

Abstract

A valve implant for glaucoma incorporated upper and lower intraocular pressure limits for outflow. The device consisted of an open Supramid tube sealed to a Silastic tube with a slit valve. The valve implants had opening pressures of 11 to 16 mm Hg and closing pressures 1 to 3 mm Hg lower. A surgical technique was developed in monkey eyes and applied later in modified form to three patients with glaucoma. In four of seven monkey eyes the implants remained in place and were patent for over one year. Follow-up studies were carried out for over six months in the three patients. In two patients the valve implants were functioning with controlled intraocular pressures. In one patient the implant migrated posteriorly. This was replaced by using a new valve and a buried fixation suture and has since functioned without problem. The valve implants were well tolerated and offered possibilities for predictable intraocular pressures after glaucoma surgery.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 814819     DOI: 10.1016/0002-9394(76)90737-6

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  15 in total

1.  A one-piece ocular drainage implant for glaucoma surgery: a preliminary report.

Authors:  M Kivalo; C Raitta; T Mononen
Journal:  Acta Vet Scand       Date:  1992       Impact factor: 1.695

2.  Clinicopathological findings 11 months after implantation of a functioning aqueous-drainage silicone implant.

Authors:  W Philipp; G Klima; K Miller
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1990       Impact factor: 3.117

3.  Ex-PRESS implant.

Authors:  A Mermoud
Journal:  Br J Ophthalmol       Date:  2005-04       Impact factor: 4.638

Review 4.  Glaucoma drainage devices; past, present, and future.

Authors:  K S Lim; B D Allan; A W Lloyd; A Muir; P T Khaw
Journal:  Br J Ophthalmol       Date:  1998-09       Impact factor: 4.638

5.  Experimental studies of aqueous filtration using the Molteno implant.

Authors:  D S Minckler; A Shammas; M Wilcox; T E Ogden
Journal:  Trans Am Ophthalmol Soc       Date:  1987

6.  Investigations of the reasons for success and failure in the anterior shunt-to-the-encircling-band procedure in the treatment of refractory glaucoma.

Authors:  S S Schocket
Journal:  Trans Am Ophthalmol Soc       Date:  1986

7.  A new method for the evacuation of aqueous humor in uncontrolled glaucoma. The vitreo-tenonian tube.

Authors:  J Haut; P Larricart; Y Le Mer; E Abboud
Journal:  Int Ophthalmol       Date:  1987-02       Impact factor: 2.031

8.  Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification.

Authors:  C E Traverso; F De Feo; A Messas-Kaplan; P Denis; S Levartovsky; E Sellem; F Badalà; Z Zagorski; A Bron; S Gandolfi; M Belkin
Journal:  Br J Ophthalmol       Date:  2005-04       Impact factor: 4.638

9.  Place of panretinal photocoagulation and trabeculectomy in the management of neovascular glaucoma.

Authors:  D W Flanagan; R K Blach
Journal:  Br J Ophthalmol       Date:  1983-08       Impact factor: 4.638

10.  A novel application of amniotic membrane in patients with bullous keratopathy.

Authors:  Hyeon Il Lee; Sang Woo Ha; Jae Chan Kim
Journal:  J Korean Med Sci       Date:  2006-04       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.