Literature DB >> 3557803

A new method for the evacuation of aqueous humor in uncontrolled glaucoma. The vitreo-tenonian tube.

J Haut, P Larricart, Y Le Mer, E Abboud.   

Abstract

The vitreo-tenonian tube is a new procedure, used in uncontrolled glaucoma, for the drainage of aqueous humor. It presents three original characteristics: it is made of a stainless metal, it is implanted in the posterior segment after vitrectomy and it drains the aqueous humor in the subtenonian space. We will describe first the surgical technique for the implantation of the tube, and then we will present the results of the first eight cases treated by this method. The advantages and drawbacks of this type of drainage are discussed: they are compared with the other surgical techniques used in cases of glaucoma which is uncontrolled by the classical methods.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3557803     DOI: 10.1007/BF00202782

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  12 in total

1.  Implants for draining neovascular glaucoma.

Authors:  A C Molteno; M M Van Rooyen; R S Bartholomew
Journal:  Br J Ophthalmol       Date:  1977-02       Impact factor: 4.638

2.  Molteno drainage implant for neovascular glaucoma.

Authors:  E Ancker; A C Molteno
Journal:  Trans Ophthalmol Soc U K       Date:  1982-04

3.  Anterior chamber tube shunt to an encircling band in the treatment of neovascular glaucoma.

Authors:  S S Schocket; V Lakhanpal; R D Richards
Journal:  Ophthalmology       Date:  1982-10       Impact factor: 12.079

4.  Krupin-Denver valve and neovascular glaucoma.

Authors:  G E Sutton; J C Popp; R E Records
Journal:  Trans Ophthalmol Soc U K       Date:  1982-04

5.  A pars plana filtering procedure combined with lensectomy and vitrectomy for neovascular for neovascular glaucoma.

Authors:  S H Sinclair; T M Aaberg; T A Meredith
Journal:  Am J Ophthalmol       Date:  1982-02       Impact factor: 5.258

6.  Aqueous-venous shunt for glaucoma. A further report.

Authors:  P Lee; R H Ward
Journal:  Arch Ophthalmol       Date:  1981-11

7.  Valve implants in filtering surgery.

Authors:  T Krupin; S M Podos; B Becker; J B Newkirk
Journal:  Am J Ophthalmol       Date:  1976-02       Impact factor: 5.258

8.  Silicone tube and gutter in advanced glaucoma.

Authors:  N J Sarkies; R A Hitchings
Journal:  Trans Ophthalmol Soc U K       Date:  1985

9.  Filtering valve implant surgery for eyes wtih neovascular glaucoma.

Authors:  T Krupin; P Kaufman; A Mandell; R Ritch; C Asseff; S M Podos; B Becker
Journal:  Am J Ophthalmol       Date:  1980-03       Impact factor: 5.258

10.  Experience with the Molteno long tube implant.

Authors:  R D Brown; J E Cairns
Journal:  Trans Ophthalmol Soc U K       Date:  1983
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.