Literature DB >> 2227496

Clinicopathological findings 11 months after implantation of a functioning aqueous-drainage silicone implant.

W Philipp1, G Klima, K Miller.   

Abstract

An aqueous-drainage silicone device was implanted in a 57-year-old diabetic patient with neovascular glaucoma after failure of conventional therapy. Postoperative intraocular pressure (IOP) was well controlled, ranging between 10 and 20 mm Hg without the use of supplemental agents. Despite the normal IOP, the eye became painful and amaurotic 11 months after implantation due to progression of the retinopathy accompanied by the development of severe tractional retinal detachment. Enucleation was performed and the eye underwent histopathological examination. The filtering bleb around the silicone plate of the implant on the equatorial sclera was lined with a thick layer of collagenous connective tissue. Numerous microcystic spaces could be seen in the bleb wall by light microscopy. Electron microscopy confirmed this finding; in addition, only a meshwork of collagen fibre-like bundles was visible at some areas of the innermost bleb wall. Control of IOP in spite of bleb fibrosis in this particular case may have been due to a loss of matrix components and to the formation of microcystic spaces in the bleb wall, which seem likely to be channels for the passage of aqueous humor.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2227496     DOI: 10.1007/bf00927266

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  30 in total

1.  The inhibitory effect of aqueous humor on the growth of cells in tissue cultures.

Authors:  W KORNBLUETH; E TENENBAUM
Journal:  Am J Ophthalmol       Date:  1956-07       Impact factor: 5.258

2.  Experimental studies of aqueous filtration using the Molteno implant.

Authors:  D S Minckler; A Shammas; M Wilcox; T E Ogden
Journal:  Trans Am Ophthalmol Soc       Date:  1987

3.  [Animal experiment studies of an implant in glaucoma surgery].

Authors:  R Wertheimer; H von Denffer; E Fabian
Journal:  Fortschr Ophthalmol       Date:  1986

4.  [Clinical experiences using a silicone implant in glaucoma with a severely changed chamber angle].

Authors:  H von Denffer; R Wertheimer; E Fabian
Journal:  Fortschr Ophthalmol       Date:  1986

5.  Rubeosis iridis and neovascular glaucoma. Evaluation of cyclocryotherapy.

Authors:  R M Feibel; J F Bigger
Journal:  Am J Ophthalmol       Date:  1972-11       Impact factor: 5.258

6.  Implants for draining neovascular glaucoma.

Authors:  A C Molteno; M M Van Rooyen; R S Bartholomew
Journal:  Br J Ophthalmol       Date:  1977-02       Impact factor: 4.638

7.  Filtration surgery in the treatment of neovascular glaucoma.

Authors:  R C Allen; A R Bellows; B T Hutchinson; S D Murphy
Journal:  Ophthalmology       Date:  1982-10       Impact factor: 12.079

8.  The optimal design of drainage implants for glaucoma.

Authors:  A C Molteno
Journal:  Trans Ophthalmol Soc N Z       Date:  1981

9.  A long Krupin-Denver valve implant attached to a 180 degrees scleral explant for glaucoma surgery.

Authors:  T Krupin; R Ritch; C B Camras; A J Brucker; T O Muldoon; J Serle; S M Podos; S H Sinclair
Journal:  Ophthalmology       Date:  1988-09       Impact factor: 12.079

10.  Clinical experience with the single-plate Molteno implant in complicated glaucomas.

Authors:  D S Minckler; D K Heuer; B Hasty; G Baerveldt; R C Cutting; W E Barlow
Journal:  Ophthalmology       Date:  1988-09       Impact factor: 12.079

View more
  1 in total

1.  Water Drinking Test: Intraocular Pressure Changes after Tube Surgery and Trabeculectomy.

Authors:  Mohammad Reza Razeghinejad; Zahra Tajbakhsh; Mohammad Hossein Nowroozzadeh; Masoumeh Masoumpour
Journal:  J Ophthalmic Vis Res       Date:  2017 Oct-Dec
  1 in total