Literature DB >> 8133761

Signal targeting with alternating radiofrequency (STAR) sequences: application to MR angiography.

R R Edelman1, B Siewert, M Adamis, J Gaa, G Laub, P Wielopolski.   

Abstract

We describe a time of flight subtraction method for cine MR angiography that provides nearly perfect suppression of background signal intensity with excellent flow contrast. The method consists of a preparation phase, during which the longitudinal magnetization of the target tissue is inverted on alternate acquisitions and the background tissue is presaturated, followed by a readout phase using a cine segmented turboFLASH sequence with a shared echo modification to improve temporal resolution. With appropriate alternation of the phases of the radiofrequency excitation pulses, there is cancellation of the background signal intensity but flow signal is optimized. By using a thick section (up to 25 mm), substantial portions of the vascular territory are encompassed in a single plane. This permits rapid, dynamic assessment of flow patterns in areas such as the circle of Willis, carotid bifurcation, or renal arteries. Applications of the method for bright and dark blood cine MR angiography are demonstrated.

Mesh:

Year:  1994        PMID: 8133761     DOI: 10.1002/mrm.1910310219

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  40 in total

Review 1.  Functional magnetic resonance imaging: imaging techniques and contrast mechanisms.

Authors:  A M Howseman; R W Bowtell
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  1999-07-29       Impact factor: 6.237

2.  Microscopic spin tagging (MiST) for flow imaging.

Authors:  Silvia Olt; Peter Schmitt; Florian Fidler; Axel Haase; Peter M Jakob
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

3.  Unenhanced dynamic MR angiography: high spatial and temporal resolution by using true FISP-based spin tagging with alternating radiofrequency.

Authors:  Lirong Yan; Sumei Wang; Yan Zhuo; Ronald L Wolf; Michael F Stiefel; Jing An; Yongquan Ye; Qian Zhang; Elias R Melhem; Danny J J Wang
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

4.  Time spatial labeling inversion pulse cerebral MR angiography without subtraction by use of dual inversion recovery background suppression.

Authors:  Yoshiyuki Ishimori; Masahiko Monma; Hiraku Kawamura; Tomoko Miyata
Journal:  Radiol Phys Technol       Date:  2010-12-01

5.  Changes in AVM angio-architecture and hemodynamics after stereotactic radiosurgery assessed by dynamic MRA and phase contrast flow assessments: a prospective follow-up study.

Authors:  Lydia Schuster; E Schenk; F Giesel; T Hauser; L Gerigk; A Zabel-Du-Bois; Marco Essig
Journal:  Eur Radiol       Date:  2010-12-22       Impact factor: 5.315

6.  Automated flow quantification for spin labeling MR imaging.

Authors:  Taichiro Shiodera; Shuhei Nitta; Tomoyuki Takeguchi; Masao Yui; Yuichi Yamashita; Takao Yamamoto; Shinya Yamada
Journal:  MAGMA       Date:  2013-12-31       Impact factor: 2.310

7.  Feasibility of MR perfusion-weighted imaging by use of a time-spatial labeling inversion pulse.

Authors:  Yoshiyuki Ishimori; Hiraku Kawamura; Masahiko Monma
Journal:  Radiol Phys Technol       Date:  2013-05-24

8.  Two-dimensional coronary MRA: limitations and artifacts.

Authors:  A J Duerinckx; D P Atkinson; J Mintorovitch; O P Simonetti; M K Vrman
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

Review 9.  Ultra-high-speed MR imaging.

Authors:  C P Davis; G C McKinnon; J F Debatin; G K von Schulthess
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

Review 10.  Perfusion MRI: the five most frequently asked technical questions.

Authors:  Marco Essig; Mark S Shiroishi; Thanh Binh Nguyen; Marc Saake; James M Provenzale; David Enterline; Nicoletta Anzalone; Arnd Dörfler; Alex Rovira; Max Wintermark; Meng Law
Journal:  AJR Am J Roentgenol       Date:  2013-01       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.