Automated flow quantification for spin labeling MR imaging.

Taichiro Shiodera1, Shuhei Nitta, Tomoyuki Takeguchi, Masao Yui, Yuichi Yamashita, Takao Yamamoto, Shinya Yamada.   

Abstract

OBJECTIVE: The Time-Spatial Labeling Inversion Pulse (Time-SLIP) technique enables tracing of regional fluid flows without the use of contrast medium. The objective of this study is to quantify automatically slow and complex fluid flows using the Time-SLIP technique.
MATERIALS AND METHODS: Series images were acquired with a 1.5-T MRI scanner using the Time-SLIP technique with half-Fourier fast spin-echo (FSE) and balanced steady-state free precession (bSSFP) sequences. In this method, labeled fluid regions in images were automatically detected based on image processing techniques for a given point. The flow velocity of the labeled fluid region was calculated using regression fitting for the region's position. To evaluate our method, constant and non-constant laminar flows in a water phantom were studied. In addition, volunteer experiments were conducted to quantify the flow of cerebrospinal fluid.
RESULTS: In the constant flow experiments the correlation factor r (2) between the flow velocity calculated from our method and the laminar peak velocity calculated from the volumetric flow rate was 0.9992 for the FSE sequence and 0.9982 for the bSSFP sequence. In the non-constant flow study, the flow velocity was calculated accurately for any period inversion time even when the flow velocity was changed, and the quantification error was negligible. In the volunteer experiments, r (2) between the flow velocity calculated by the proposed method and that obtained by manual annotation was 0.9383.
CONCLUSION: The experimental results showed that our proposed method can quickly and accurately provide information on flow velocities especially for slower and complex flows. Our method is, therefore, expected to be useful in diagnostic support systems.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24378855     DOI: 10.1007/s10334-013-0416-1

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  6 in total

Review 1.  Phase contrast cine magnetic resonance imaging.

Authors:  N J Pelc; R J Herfkens; A Shimakawa; D R Enzmann
Journal:  Magn Reson Q       Date:  1991-10

2.  Visualization of cerebrospinal fluid movement with spin labeling at MR imaging: preliminary results in normal and pathophysiologic conditions.

Authors:  Shinya Yamada; Mitsue Miyazaki; Hitoshi Kanazawa; Minako Higashi; Yukuo Morohoshi; Stefan Bluml; J Gordon McComb
Journal:  Radiology       Date:  2008-11       Impact factor: 11.105

Review 3.  Nonenhanced MR angiography.

Authors:  Mitsue Miyazaki; Vivian S Lee
Journal:  Radiology       Date:  2008-07       Impact factor: 11.105

4.  MR angiography by selective inversion recovery.

Authors:  D G Nishimura; A Macovski; J M Pauly; S M Conolly
Journal:  Magn Reson Med       Date:  1987-02       Impact factor: 4.668

Review 5.  Phase contrast cine magnetic resonance imaging: normal cerebrospinal fluid oscillation and applications to hydrocephalus.

Authors:  T P Naidich; N R Altman; S M Gonzalez-Arias
Journal:  Neurosurg Clin N Am       Date:  1993-10       Impact factor: 2.509

6.  Signal targeting with alternating radiofrequency (STAR) sequences: application to MR angiography.

Authors:  R R Edelman; B Siewert; M Adamis; J Gaa; G Laub; P Wielopolski
Journal:  Magn Reson Med       Date:  1994-02       Impact factor: 4.668

  6 in total
  1 in total

Review 1.  Cerebrospinal fluid physiology: visualization of cerebrospinal fluid dynamics using the magnetic resonance imaging Time-Spatial Inversion Pulse method.

Authors:  Shinya Yamada
Journal:  Croat Med J       Date:  2014-08-28       Impact factor: 1.351