Feasibility of MR perfusion-weighted imaging by use of a time-spatial labeling inversion pulse.

Yoshiyuki Ishimori1, Hiraku Kawamura, Masahiko Monma.   

Abstract

Perfusion-weighted imaging (PWI) by use of arterial spin labeling (ASL) has been introduced to the clinical setting. However, it is not widely available because it requires specialized pulse sequences. Imaging using a time-spatial labeling inversion pulse (time-SLIP), which is a magnetic resonance angiography (MRA) technique that is based on ASL, can be used in various situations. In this study, we examined the feasibility of time-SLIP PWI. Two types of time-SLIP sequences were evaluated: (1) a single inversion recovery (IR) pulse sequence, which is the same as that used in conventional time-SLIP MRA except for the timing of data acquisition, and (2) a dual IR pulse sequence, where a second, non-selective, IR pulse was added during the inflow time to suppress background signals. Subtraction processing is performed between the "on" and "off" settings of the first IR pulse (time-SLIP tag) to obtain PWI. The average signal intensity was measured in a uniform phantom as the residual of the background, and in five healthy subjects as the perfusion signal. The average signal-to-noise ratio (SNR) was also measured in the five subjects. All imaging was performed with a 1.5-T MR scanner. Images using the dual IR method showed lower background signals and higher perfusion signals compared with images using the single IR method. However, the SNR was lower in images with the dual IR method. These results demonstrate that a time-SLIP, which is an MRA method, can be used for obtaining cerebral PWI simply by adjusting the imaging parameters.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23703027     DOI: 10.1007/s12194-013-0219-0

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  23 in total

Review 1.  Methodology of brain perfusion imaging.

Authors:  E L Barbier; L Lamalle; M Décorps
Journal:  J Magn Reson Imaging       Date:  2001-04       Impact factor: 4.813

2.  Non-contrast-enhanced hepatic MR angiography with true steady-state free-precession and time spatial labeling inversion pulse: optimization of the technique and preliminary results.

Authors:  Kotaro Shimada; Hiroyoshi Isoda; Tomohisa Okada; Yoji Maetani; Shigeki Arizono; Yuusuke Hirokawa; Toshikazu Kamae; Kaori Togashi
Journal:  Eur J Radiol       Date:  2008-02-04       Impact factor: 3.528

Review 3.  Nonenhanced MR angiography.

Authors:  Mitsue Miyazaki; Vivian S Lee
Journal:  Radiology       Date:  2008-07       Impact factor: 11.105

4.  Visualization of external carotid artery and its branches: non-contrast-enhanced MR angiography using balanced steady-state free-precession sequence and a time-spatial labeling inversion pulse.

Authors:  Naoe Satogami; Tomohisa Okada; Takashi Koyama; Kimio Gotoh; Toshikazu Kamae; Kaori Togashi
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

5.  Clinical application of arterial spin-labeling MR imaging in patients with carotid stenosis: quantitative comparative study with single-photon emission CT.

Authors:  Y Uchihashi; K Hosoda; I Zimine; A Fujita; M Fujii; K Sugimura; E Kohmura
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-14       Impact factor: 3.825

Review 6.  Perfusion MRI using dynamic-susceptibility contrast MRI: quantification issues in patient studies.

Authors:  Fernando Calamante
Journal:  Top Magn Reson Imaging       Date:  2010-04

7.  MR angiography by selective inversion recovery.

Authors:  D G Nishimura; A Macovski; J M Pauly; S M Conolly
Journal:  Magn Reson Med       Date:  1987-02       Impact factor: 4.668

8.  Signal targeting with alternating radiofrequency (STAR) sequences: application to MR angiography.

Authors:  R R Edelman; B Siewert; M Adamis; J Gaa; G Laub; P Wielopolski
Journal:  Magn Reson Med       Date:  1994-02       Impact factor: 4.668

Review 9.  Arterial spin-labeled MR perfusion imaging: clinical applications.

Authors:  Jeffrey M Pollock; Huan Tan; Robert A Kraft; Christopher T Whitlow; Jonathan H Burdette; Joseph A Maldjian
Journal:  Magn Reson Imaging Clin N Am       Date:  2009-05       Impact factor: 2.266

10.  Minimizing acquisition time of arterial spin labeling at 3T.

Authors:  María A Fernández-Seara; Brian L Edlow; Angela Hoang; Jiongjiong Wang; David A Feinberg; John A Detre
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

View more
  1 in total

1.  Comparative study of DSC-PWI and 3D-ASL in ischemic stroke patients.

Authors:  Shui-Xia Zhang; Yi-Hao Yao; Shun Zhang; Wen-Jie Zhu; Xiang-Yu Tang; Yuan-Yuan Qin; Ling-Yun Zhao; Cheng-Xia Liu; Wen-Zhen Zhu
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2015-12-16
  1 in total