Intra-operative blood glucose measurements. The effect of haematocrit on glucose test strips.

E A Smith1, E S Kilpatrick.   

Abstract

Variations in haematocrit are known to affect the accuracy of reagent strip tests for glucose. We have investigated 10 patients during cardiopulmonary bypass, where intra-operative decreases in haematocrit occur. Whole blood glucose concentrations were measured on five occasions at 30 min intervals during the procedure using the Glucometer II, One Touch II and Reflolux II meters as well as a reference instrument (YSI Model 23 AM). Haematocrits were recorded simultaneously. Overall, for every 10% fall in haematocrit, Glucometer II measurements rose by 22% (r = 0.74, p < 0.00001), One Touch II measurements fell by 3% (r = 0.44, p < 0.002) and the Reflolux II measurements showed no significant variation. The One Touch II showed closer agreement to the reference (mean bias 0.3 mmol.l-1 (95% between +0.86 and -0.26)) than the Reflolux II (bias 1.58 (+3.40 to -0.24)) or the Glucometer II (bias 3.25 (+6.18 to 0.32)). Thus, depending on the meter used, spuriously large intraoperative changes in blood glucose may seem to arise where patient haematocrit varies.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8129121     DOI: 10.1111/j.1365-2044.1994.tb03369.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  7 in total

1.  Hematocrit interference of blood glucose meters for patient self-measurement.

Authors:  Sanja Ramljak; John Paul Lock; Christina Schipper; Petra B Musholt; Thomas Forst; Martha Lyon; Andreas Pfützner
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

2.  Determination of hematocrit interference in blood samples derived from patients with different blood glucose concentrations.

Authors:  Andreas Pfützner; Christina Schipper; Sanja Ramljak; Frank Flacke; Jochen Sieber; Thomas Forst; Petra B Musholt
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

3.  Evaluation of hematocrit interference with MyStar extra and seven competitive devices.

Authors:  Filiz Demircik; Sanja Ramljak; Iris Hermanns; Anke Pfützner; Andreas Pfützner
Journal:  J Diabetes Sci Technol       Date:  2014-12-30

4.  Blood glucose meters employing dynamic electrochemistry are stable against hematocrit interference in a laboratory setting.

Authors:  Andreas Pfützner; Petra B Musholt; Christina Schipper; Filiz Demircik; Carina Hengesbach; Frank Flacke; Jochen Sieber; Thomas Forst
Journal:  J Diabetes Sci Technol       Date:  2013-11-01

5.  Dynamic electrochemistry corrects for hematocrit interference on blood glucose determinations with patient self-measurement devices.

Authors:  Petra B Musholt; Christina Schipper; Nicole Thomé; Sanja Ramljak; Marc Schmidt; Thomas Forst; Andreas Pfützner
Journal:  J Diabetes Sci Technol       Date:  2011-09-01

6.  Accuracy of Blood Glucose Measurement and Blood Glucose Targets.

Authors:  Gert-Jan Eerdekens; Steffen Rex; Dieter Mesotten
Journal:  J Diabetes Sci Technol       Date:  2020-02-11

Review 7.  Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring.

Authors:  Hima Zafar; Asma Channa; Varun Jeoti; Goran M Stojanović
Journal:  Sensors (Basel)       Date:  2022-01-14       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.